![](/images/new-backgrounds/1316430/31643075x1.webp)
38 en Configuration | DINION 5000 AN |
|
|
5.6.4Alarm I/O submenu
Item | Selection | Description |
|
|
|
Input | None, high, | Select none to disable the alarm input. |
| low | Select |
|
| alarm input connector. |
|
|
|
Input action | None, | Selects the operating mode of the |
| Mode 1 to 6, | camera when the alarm input is active. |
| Night mode |
|
|
|
|
Output | Normally | Selects the relay output mode. |
| open, |
|
| Normally |
|
| closed |
|
|
|
|
Output action | VMD, | VMD: - output relay closes on VMD |
| Ext. device, | alarms. |
| Night mode, | External device: - make the output |
| Filter toggle | relay available to remote |
|
| communication devices. |
|
| Night mode: - output relay closes when |
|
| camera is in monochrome mode. |
|
| Filter toggle: - output relay closes just |
|
| before the IR filter starts moving and |
|
| opens when video level has stabilized |
|
| (2 to 3 seconds) |
|
|
|
EXIT |
| Returns to Install menu. |
|
|
|
| Installation Manual | Bosch Security Systems |