Axis Communications M1114E user manual Advanced, Control Queue, Controls

Page 25

AXIS M1114–E

PTZ (Pan Tilt Zoom)

4.Select an available preset position and click Apply.

5.Specify the View Time in seconds or minutes.

6.Specify the View Order or select the Random view order option.

7.Click Save.

To modify or remove guard tours, go to PTZ > Guard Tour, select the guard tour in the Guard Tour List and click Modify/Remove.

For more information see the online help .

Advanced

Controls

Advanced PTZ settings can be configured under PTZ > Advanced > Controls.

The Panel Shortcut Command Buttons list shows the user-defined buttons that can be accessed from the Live View page’s Ctrl panel. These buttons can be used to provide direct access to commands issued using the VAPIX® application programming interface. Click Add to add a new shortcut command button.

The following PTZ controls are enabled by default:

Pan control

Tilt control

Zoom control

To disable specific controls, deselect the options under Enable/Disable controls.

Control Queue

The administrator can set up a queue for PTZ controllers from PTZ > Control Queue. Once set up, the PTZ Control Queue buttons appear in the Live View page offering one viewer exclusive control for a limited period of time. Other users will be placed in queue.

A user who belongs to a group (see Users on page 38) with a higher PTZ priority can go before other users in the queue and take control of the product. The order of priority is as follows:

1.Administrator — An administrator takes over PTZ control regardless of who is first in queue. The administrator will be removed from the queue 60 seconds after the last PTZ control command.

2.Event — The Axis product can be configured to go to a preset position when triggered by an alarm (see Events on page 31). The event will immediately be placed first in the queue except when an administrator is in control.

3.Operator — Same as administrator but with lower priority

4.Guard Tour — A guard tour (see page 24) has PTZ control for an indefinite period of time. It may be overridden by an operator, event or administrator. The guard tour will resume when higher priority groups leave the queue.

5.Viewer — Multiple viewers must wait for their turn. The viewer has 60 seconds PTZ control before control is passed on to the next viewer in queue.

Note

The administrator can enable and disable PTZ controls for selected users.

To identify different users in the viewer group, cookies must be enabled on the client.

25

Image 25
Contents Axis M1114-E Legal Considerations About this DocumentLiability Intellectual Property RightsLearn More SupportAxis M1114-E Table of ContentsPerformance Considerations Network Connector Connectors and ButtonsHardware Overview Control ButtonPower LED Indication LED IndicatorsStatus LED Indication Network LED IndicationAccess from a Browser Access the ProductAccess from the Internet Set the Root PasswordLive View Set Power Line FrequencyClick Create self-signed certificate Controls on the Live View Go to Setup EventsAxis Media Control viewer toolbar Manual TriggerPTZ Controls Media Streams How to Stream H.264Axis Media Control AMC QuickTimeTM. The following paths can be used Alternative Methods of Accessing the Video StreamAxis M1114-E Basic Setup Set Up the ProductFocus Adjustment Back Focus AdjustmentVideo Stream VideoPixel Counter ImageStream Profiles Click Save to apply the new settings264 Exposure Settings Camera SettingsView Area Image AppearanceOverlay Image OverlayGo to Video Video Stream and select the Image tab Go to Video Overlay ImageGo to Events Action Rules Use Overlay Text in an Action RulePrivacy Mask Default Viewer for Browsers Configure the Live ViewViewer Settings Browser Viewer DescriptionUser Defined Links PTZ Pan Tilt Zoom Preset PositionsGuard Tour Advanced Operator Same as administrator but with lower priorityControl Queue ControlsCamera Tampering DetectorsMotion Detection Go to Detectors Camera TamperingMotion Detection Parameters Set Up Motion Detection WindowsAxis M1114-E Go to Setup Applications Install ApplicationApplications Application LicensesAxis M1114-E Events Set Up Action RulesConvert Event Types to Action Rules Go to Events Action Rules and click AddActions TriggersRecipient Types Add RecipientsGo to Events Recipients and click Add Recipient Use with actionSet Up Email Recipients Set Up RecurrencesCreate Schedules Go to Events Schedules and click AddAxis M1114-E Recording List RecordingsContinuous Recording Go to Recordings ListLanguages Security System OptionsUsers IP Address FilterCertificates IeeeGo to System Options Security Ieee Go to Setup System Options Security Certificates Basic TCP/IP SettingsDate & Time NetworkIPv6 Address Configuration IPv4 Address ConfigurationAxis Internet Dynamic DNS Service ARP/PingDNS Configuration Advanced TCP/IP SettingsNTP Configuration Host Name ConfigurationFTP NAT traversal port mapping for IPv4UPnPTM can be disabled under System Options Network UPnPTM QoS Quality of ServiceUPnPTM RTP/H.264Storage MaintenanceBonjour Network ShareSupport Overview SupportSystem Overview Logs & ReportsPlain Config Reset to Factory Default SettingsScripting File UploadUpgrade the Firmware TroubleshootingEmergency Recovery Procedure Check the FirmwareProblems setting the IP address Symptoms, Possible Causes and Remedial ActionsProduct cannot be accessed from a browser Product is accessible locally but not externallyStatus and Network indicator LEDs are flashing red rapidly Problems with streaming H.264Video and image problems, general Video Camera SettingsStorage disruption Storage and disk management problemsRe-mount the storage device Reformat the SD card and then click MountTechnical Specifications Installation Function/group Specifications System ApplicationMaintenance General Casing PowerPerformance Considerations M2.5