Axis Communications M1114E user manual Reset to Factory Default Settings, Scripting, File Upload

Page 47

AXIS M1114–E

System Options

Advanced

Scripting

Scripting allows experienced users to customize and use their own scripts.

NOTICE

Improper use may cause unexpected behavior and loss of contact with the Axis product.

Axis strongly recommends that you do not use this function unless you understand the consequences. Axis Support does not provide assistance for problems with customized scripts.

To open the Script Editor, go to System Options > Advanced > Scripting. If a script causes problems, reset the product to its factory default settings, see page 47.

For more information, see www.axis.com/developer

File Upload

Files, for example webpages and images, can be uploaded to the Axis product and used as custom settings. To upload a file, go to System Options > Advanced > File Upload.

Uploaded files are accessed through http://<ip address>/local/<user>/<file name> where <user> is the selected user group (viewer, operator or administrator) for the uploaded file.

Plain Config

Plain Config is for advanced users with experience of Axis product configuration. Most parameters can be set and modified from this page.

To open Plain Config, go to System Options > Advanced > Plain Config . Axis Support does not provide assistance.

Reset to Factory Default Settings

Important

Reset to factory default should be used with caution. A reset to factory default will reset all settings, including the IP address, to the factory default values.

Note

The installation and management software tools are available on the CD supplied with the product and from the support pages on www.axis.com/techsup

To reset the product to the factory default settings:

1.Disconnect power from the product.

2.Press and hold the control button and reconnect power. See Hardware Overview on page 6 .

3.Keep the control button pressed for about 15–30 seconds until the status LED indicator flashes amber.

4.Release the control button. The process is complete when the status LED indicator turns green. The product has been reset to the factory default settings. If no DHCP server is available on the network, the default IP address is 192.168.0.90

5.Using the installation and management software tools, assign an IP address, set the password, and access the video stream. It is also possible to reset parameters to factory default via the web interface. Go to Setup > System Options > Maintenance.

47

Image 47
Contents Axis M1114-E Intellectual Property Rights About this DocumentLegal Considerations LiabilityLearn More SupportAxis M1114-E Table of ContentsPerformance Considerations Control Button Connectors and ButtonsNetwork Connector Hardware OverviewNetwork LED Indication LED IndicatorsPower LED Indication Status LED IndicationSet the Root Password Access the ProductAccess from a Browser Access from the InternetClick Create self-signed certificate Set Power Line FrequencyLive View Manual Trigger Go to Setup EventsControls on the Live View Axis Media Control viewer toolbarPTZ Controls Axis Media Control AMC How to Stream H.264Media Streams QuickTimeTM. The following paths can be used Alternative Methods of Accessing the Video StreamAxis M1114-E Back Focus Adjustment Set Up the ProductBasic Setup Focus AdjustmentImage VideoVideo Stream Pixel Counter264 Click Save to apply the new settingsStream Profiles Image Appearance Camera SettingsExposure Settings View AreaGo to Video Overlay Image OverlayOverlay Image Go to Video Video Stream and select the Image tabGo to Events Action Rules Use Overlay Text in an Action RulePrivacy Mask Browser Viewer Description Configure the Live ViewDefault Viewer for Browsers Viewer SettingsUser Defined Links Guard Tour Preset PositionsPTZ Pan Tilt Zoom Controls Operator Same as administrator but with lower priorityAdvanced Control QueueGo to Detectors Camera Tampering DetectorsCamera Tampering Motion DetectionMotion Detection Parameters Set Up Motion Detection WindowsAxis M1114-E Application Licenses Install ApplicationGo to Setup Applications ApplicationsAxis M1114-E Go to Events Action Rules and click Add Set Up Action RulesEvents Convert Event Types to Action RulesActions TriggersRecipient Use with action Add RecipientsRecipient Types Go to Events Recipients and click AddGo to Events Schedules and click Add Set Up RecurrencesSet Up Email Recipients Create SchedulesAxis M1114-E Go to Recordings List RecordingsRecording List Continuous RecordingLanguages IP Address Filter System OptionsSecurity UsersGo to System Options Security Ieee IeeeCertificates Network Basic TCP/IP SettingsGo to Setup System Options Security Certificates Date & TimeARP/Ping IPv4 Address ConfigurationIPv6 Address Configuration Axis Internet Dynamic DNS ServiceHost Name Configuration Advanced TCP/IP SettingsDNS Configuration NTP ConfigurationFTP NAT traversal port mapping for IPv4RTP/H.264 QoS Quality of ServiceUPnPTM can be disabled under System Options Network UPnPTM UPnPTMNetwork Share MaintenanceStorage BonjourLogs & Reports SupportSupport Overview System OverviewFile Upload Reset to Factory Default SettingsPlain Config ScriptingCheck the Firmware TroubleshootingUpgrade the Firmware Emergency Recovery ProcedureProduct is accessible locally but not externally Symptoms, Possible Causes and Remedial ActionsProblems setting the IP address Product cannot be accessed from a browserVideo Camera Settings Problems with streaming H.264Status and Network indicator LEDs are flashing red rapidly Video and image problems, generalReformat the SD card and then click Mount Storage and disk management problemsStorage disruption Re-mount the storage deviceTechnical Specifications Power Function/group Specifications System ApplicationInstallation Maintenance General CasingPerformance Considerations M2.5