Axis Communications M1114E user manual Symptoms, Possible Causes and Remedial Actions, Basic

Page 49

AXIS M1114–E

Troubleshooting

5. Reinstall the product, referring to the Installation Guide.

If the emergency recovery procedure does not get the product up and running again, contact Axis support at www.axis.com/techsup/

Symptoms, Possible Causes and Remedial Actions

Problems setting the IP address

When using ARP/Ping

Try the installation again. The IP address must be set within two minutes after power has been

 

applied to the product. Ensure the Ping length is set to 408. For instructions, see .

The product is located on a

If the IP address intended for the product and the IP address of the computer used to access the

different subnet

product are located on different subnets, you will not be able to set the IP address. Contact your

 

network administrator to obtain an IP address.

The IP address is being used by another device

Possible IP address conflict with another device on the same subnet.

Disconnect the Axis product from the network. Run the Ping command (in a Command/DOS window, type ping and the IP address of the product):

If you receive: Reply from <IP address>: bytes=32; time=10...

this means that the IP address may already be in use by another device on the network. Obtain a new IP address from the network administrator and reinstall the product.

If you receive: Request timed out, this means that the IP address is available for use with the Axis product. Check all cabling and reinstall the product.

The static IP address in the Axis product is used before the DHCP server sets a dynamic address. This means that if the same default static IP address is also used by another device, there may be problems accessing the product.

The product cannot be accessed from a browser

Cannot log in

The IP address has been changed by DHCP

Certificate error when using IEEE 802.1X

When HTTPS is enabled, ensure that the correct protocol (HTTP or HTTPS) is used when attempting to log in. You may need to manually type http or https in the browser’s address field.

If the password for the user root is lost, the product must be reset to the factory default settings. See Reset to Factory Default Settings on page 47.

IP addresses obtained from a DHCP server are dynamic and may change. If the IP address has been changed, use AXIS IP Utility or AXIS Camera Management to locate the product on the network. Identify the product using its model or serial number, or by the DNS name (if the name has been configured).

If required, a static IP address can be assigned manually. For instructions, see the Installation and Management Software CD or the document Assign an IP Address and Access the Video Stream on Axis Support web at www.axis.com/techsup.

For authentication to work properly, the date and time settings in the Axis product should be synchronized with an NTP server. See Date & Time on page 40.

The product is accessible locally but not externally

Router configuration

To configure your router to allow incoming data traffic to the Axis product, enable the NAT-traversal

 

feature which will attempt to automatically configure the router to allow access to the Axis

 

product, see NAT traversal (port mapping) for IPv4 on page 43. The router must support UPnPTM.

Firewall protection

Check the Internet firewall with your network administrator.

Default routers required

Check if you need to configure the router settings from System Options > Network > TCP/IP >

 

Basic.

49

Image 49
Contents Axis M1114-E Legal Considerations About this DocumentLiability Intellectual Property RightsLearn More SupportAxis M1114-E Table of ContentsPerformance Considerations Network Connector Connectors and ButtonsHardware Overview Control ButtonPower LED Indication LED IndicatorsStatus LED Indication Network LED IndicationAccess from a Browser Access the ProductAccess from the Internet Set the Root PasswordLive View Set Power Line FrequencyClick Create self-signed certificate Controls on the Live View Go to Setup EventsAxis Media Control viewer toolbar Manual TriggerPTZ Controls Media Streams How to Stream H.264Axis Media Control AMC QuickTimeTM. The following paths can be used Alternative Methods of Accessing the Video StreamAxis M1114-E Basic Setup Set Up the ProductFocus Adjustment Back Focus AdjustmentVideo Stream VideoPixel Counter ImageStream Profiles Click Save to apply the new settings264 Exposure Settings Camera SettingsView Area Image AppearanceOverlay Image OverlayGo to Video Video Stream and select the Image tab Go to Video Overlay ImageGo to Events Action Rules Use Overlay Text in an Action RulePrivacy Mask Default Viewer for Browsers Configure the Live ViewViewer Settings Browser Viewer DescriptionUser Defined Links PTZ Pan Tilt Zoom Preset PositionsGuard Tour Advanced Operator Same as administrator but with lower priorityControl Queue ControlsCamera Tampering DetectorsMotion Detection Go to Detectors Camera TamperingMotion Detection Parameters Set Up Motion Detection WindowsAxis M1114-E Go to Setup Applications Install ApplicationApplications Application LicensesAxis M1114-E Events Set Up Action RulesConvert Event Types to Action Rules Go to Events Action Rules and click AddActions TriggersRecipient Types Add RecipientsGo to Events Recipients and click Add Recipient Use with actionSet Up Email Recipients Set Up RecurrencesCreate Schedules Go to Events Schedules and click AddAxis M1114-E Recording List RecordingsContinuous Recording Go to Recordings ListLanguages Security System OptionsUsers IP Address FilterCertificates IeeeGo to System Options Security Ieee Go to Setup System Options Security Certificates Basic TCP/IP SettingsDate & Time NetworkIPv6 Address Configuration IPv4 Address ConfigurationAxis Internet Dynamic DNS Service ARP/PingDNS Configuration Advanced TCP/IP SettingsNTP Configuration Host Name ConfigurationFTP NAT traversal port mapping for IPv4UPnPTM can be disabled under System Options Network UPnPTM QoS Quality of ServiceUPnPTM RTP/H.264Storage MaintenanceBonjour Network Share Support Overview Support System Overview Logs & ReportsPlain Config Reset to Factory Default SettingsScripting File UploadUpgrade the Firmware TroubleshootingEmergency Recovery Procedure Check the FirmwareProblems setting the IP address Symptoms, Possible Causes and Remedial ActionsProduct cannot be accessed from a browser Product is accessible locally but not externallyStatus and Network indicator LEDs are flashing red rapidly Problems with streaming H.264Video and image problems, general Video Camera SettingsStorage disruption Storage and disk management problemsRe-mount the storage device Reformat the SD card and then click MountTechnical Specifications Installation Function/group Specifications System ApplicationMaintenance General Casing PowerPerformance Considerations M2.5