AXIS Q8108-R User’s GuidePage 7
Pin assignment - I/O connector
Pin | Function |
| Notes |
| Specifications |
| ||||
number |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
1 | Output 1 |
| Open collector NPN transistor with the emitter | Max load = 500mA |
|
| ||||
|
|
|
| connected to ground when activated. |
|
|
|
| ||
2 | Output 2 |
|
|
|
|
| ||||
|
|
|
| Outputs are reserved for developer use. |
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| |
3 | Input 1 |
| Inactive for voltages less than 1V | Max input = + 30V |
|
| ||||
|
|
|
| Active for voltages more than 3V |
|
|
|
| ||
4 | Input 2 |
|
|
|
|
| ||||
|
|
|
| Only one input can be programmed via AXIS NVR |
|
|
|
| ||
5 | Input 3 |
|
|
|
| ENGLISH | ||||
| manager, see Power Configuration, on page 13 |
|
|
| ||||||
|
|
|
|
|
|
| ||||
6 | Input 4 |
|
|
|
|
| ||||
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
7 | Input 5 |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
8 | Input 6 |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
9 | Input 7 |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
10 | Input 8 |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| |
11 | 5V DC |
| Can be used to power auxiliary equipment. | Max load = 250mA |
|
| ||||
| Power |
| Note: |
|
|
|
|
| ||
|
|
|
| This pin can only be used as power out. |
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
12 | GND |
| Ground |
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
LED indicators |
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
| |
LED |
| Color |
| Indication |
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| |
Network |
| Amber |
| Link established. |
|
|
|
|
| |
|
|
|
|
|
|
|
|
| ||
|
| Green |
| Steady for connection to 100 Mbit/s network |
|
|
|
| ||
|
| Unlit |
|
|
|
|
|
| ||
|
|
| For connection to 1Gbit/s network |
|
|
|
| |||
|
|
|
|
|
|
|
|
| ||
Power |
| Green |
| Power supplied - normal operation. |
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| |
|
| Green and |
| Battery powered |
|
|
|
|
| |
|
| Amber |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| |
|
| Unlit |
| Power off |
|
|
|
|
| |
|
|
|
|
|
|
| ||||
PoE/Link |
| Green |
| Steady | Power is being supplied to the camera |
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Flash slowly | Short circuit |
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
| 2 flash sequence | Error in PoE connection. |
|
|
| |
|
|
|
|
|
|
|
| |||
|
|
|
|
| 5 flash sequence | Connected units exceed the max load. |
|
|
| |
|
|
|
|
|
|
|
| |||
|
|
|
|
| 6 flash sequence | Connected units in the left or right group |
|
|
| |
|
|
|
|
|
| exceed the max load. |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
| Amber |
| Link established |
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|