FLEXIDOME HD VR | Installation en 23 |
|
|
Cable tree
Use the following table to identify the wires in the cable tree:
Wire color | AWG | Signal | |||
|
|
|
|
|
|
Red | 26 | +12 VDC / 24 VAC | |||
|
|
|
|
|
|
Brown | 26 | GND DC / 24 VAC | |||
|
|
|
|
|
|
Yellow / Green | 24 | Earth |
|
|
|
|
|
| |||
|
|
|
|
| |
|
|
|
|
|
|
Black / Orange | 28 | Alarm Out A | |||
|
|
|
|
|
|
White / Orange | 28 | Alarm Out B | |||
|
|
|
|
|
|
White / Violet | 28 | Ground (Alarm In) | |||
|
|
|
|
|
|
Orange / Violet | 28 | Alarm In 1 | |||
|
|
|
|
|
|
Violet | 28 | Alarm In 2 | |||
|
|
|
|
|
|
White | 28 | Audio In | |||
|
|
|
|
|
|
(Shield) | 28 | Ground (Audio In) | |||
|
|
|
|
|
|
Black | 28 | Audio Out | |||
|
|
|
|
|
|
(Shield) | 28 | Ground (Audio Out) | |||
|
|
|
|
|
|
For connections use wires of at least the same thickness.
Power connection
1.Use a class 2 power supply 24 VAC or +12 VDC.
2.Connect the power wires (red+ ,
3.Connect the earth wire (yellow/green) from the camera to the system earth of the installation to ensure correct EMC/ RFI and safety protection.
Network (and PoE) connection
1.Use a shielded twisted pair (STP) Category 5e cable, maximum length 100 meters.
2.Use the RJ45
Power is supplied to the camera via the Ethernet cable, compliant with the
Bosch Security Systems | Installation Manual |