9Maintenance

9.1Testing the network connection

The ping command can be used to check the connection between two IP addresses. This allows testing whether a device is active in the network.

1.Open the DOS command prompt.

2.Type ping followed by the IP address of the device.

If the device is found, the response appears as " Reply from ... ", followed by the number of bytes sent and the transmission time in milliseconds. Otherwise, the device cannot be accessed via the network. This might be because:

The device is not properly connected to the network. Check the cable connections in this case.

The device is not correctly integrated into the network. Check the IP address, subnet mask, and gateway address.

9.2Cleaning the bubble

The exterior of the bubble is hard coated for extra protection. If cleaning becomes necessary, only use cleaning solutions and cloths suitable for cleaning safety glass lenses. Dry the bubble thoroughly with a dry nonabrasive cloth to prevent water spots. Never scrub the bubble with any abrasive material or cleaners.

Do not use abrasive or highly alkaline cleaners on the bubble.

Do not scrape the bubble with razor blades or other sharp instruments.

Do not use Benzene, Gasoline, Acetone, or Carbon Tetrachloride on the bubble.

Do not clean bubbles in the hot sun or on very hot days

Bosch Security Systems

Installation Manual

AM18-Q0637 v1.1 2013.08

Image 39
Contents Flexidome HD VR Page Table of Contents Maintenance InstallationCamera configuration Troubleshooting10.1.1 Dimensions Safety precautions SafetyImportant safety instructions Connection in applications Type labelGrounding FCC & Ices Information FCC & Ices complianceMicroSD cards UL certificationDisclaimer Bosch notices Copyrights Introduction FeaturesNetwork video server System InformationTamper detection and motion detection Alarm I/OPower-over-Ethernet AudioRecording ConfigurationBosch Recording Station Operation with external systemsBosch Video Management System Bosch Video ClientPlanning UnpackingSystem requirements Parts InstallationSurface mounting Mounting the unitFlush mount Connections Make the connectionsConnection box Cable tree Wire colorSignal Power connectionAudio in / Audio out Alarm InputAlarm output Analog video outputMount the camera Controls FoV Camera positioning and field-of-viewTilt 1 PanTwist Adjustment procedure Using the install wizardClosing the unit Flexidome HD VR Camera configuration Day/Night switchingUser modes Protected network Browser connectionFunction test Troubleshooting Malfunction Possible causes Solution Resolving problemsLivepage Functions For example 192.168.0.1/version Customer serviceMaintenance Testing the network connectionCleaning the bubble Transfer and disposal RepairsTechnical Data SpecificationsNIN-932 IP, IBP, Ibbp NIN-832 IP, IBP, Ibbp NIN-733 IP, IBP, Ibbp Dimensions En Technical Data Page Bosch Security Systems