Bosch Appliances NIN-832 Analog video output, Alarm Input, Alarm output, Audio in / Audio out

Page 24

24 en Installation

FLEXIDOME HD VR

 

 

CAUTION!

The RJ45 female-to-female network cable connector supplied is unshielded. To comply with the EMC Alarm immunity standard (EN 50130-4) or the EMC Railway immunity standard

(EN 50121-4), a shielded twisted pair (STP) connection cable and a shielded RJ45 female-to-female network cable connector (not supplied) should be used.

Analog video output

Connect to the BNC connector to obtain an analog video signal. This is a CVBS 1 Vpp PAL or NTSC signal (depending on the selected camera base frequency).

Note:

If necessary, use an isolation transformer to avoid ground loops.

Alarm Input

Use the alarm input to connect external alarm devices such as door contacts or sensors. A zero potential make or break contact can be used as the actuator (use a bounce-free contact system).

Refer to the cable tree table to identify the wire colors for connecting the alarm input.

Configurable as active low or active high.

Alarm output

Use the alarm relay output for switching external devices such as lamps or sirens.

Refer to the cable tree table to identify the wire colors for connecting the alarm output.

In the menu system, configure the relay output to operate as either normally open (NO) or normally closed (NC).

Audio in / Audio out

The unit has full-duplex mono audio. The two-way communication can be used to connect a speaker or door

AM18-Q0637 v1.1 2013.08

Installation Manual

Bosch Security Systems

Image 24
Contents Flexidome HD VR Page Table of Contents Installation Camera configurationTroubleshooting Maintenance10.1.1 Dimensions Safety Safety precautionsImportant safety instructions Connection in applications Type labelGrounding FCC & Ices compliance FCC & Ices InformationMicroSD cards UL certificationDisclaimer Bosch notices Copyrights Features IntroductionSystem Information Network video serverAlarm I/O Power-over-EthernetAudio Tamper detection and motion detectionConfiguration RecordingOperation with external systems Bosch Video Management SystemBosch Video Client Bosch Recording StationPlanning UnpackingSystem requirements Installation PartsMounting the unit Surface mounting Flush mount Connections Make the connectionsConnection box Wire color SignalPower connection Cable treeAlarm Input Alarm outputAnalog video output Audio in / Audio outMount the camera Controls Camera positioning and field-of-view FoV1 Pan TiltTwist Using the install wizard Adjustment procedureClosing the unit Flexidome HD VR Camera configuration Day/Night switchingUser modes Browser connection Protected networkTroubleshooting Function testResolving problems Malfunction Possible causes SolutionLivepage Functions Customer service For example 192.168.0.1/versionMaintenance Testing the network connectionCleaning the bubble Repairs Transfer and disposalTechnical Data SpecificationsNIN-932 IP, IBP, Ibbp NIN-832 IP, IBP, Ibbp NIN-733 IP, IBP, Ibbp Dimensions En Technical Data Page Bosch Security Systems