External Alarm Connector

Quick Start

Interface Connectors

External Alarm Connector

The external alarm 6-pin connector with one input pair (pins 5 and 6)

and two output pairs (pins 1 and 2 - major alarms; pins 3 and 4 - minor A

alarms).

L

A

R

M

L 6

Manual background 5

Manual background 4

Manual background 3

Manual background 2 Manual background 1

The pinouts are as follows:

Pin #

Description

Explanation

 

 

 

1

Major Alarm +

The major alarm output is available for power supply or

2

Major Alarm -

major alarm failure alerting. The maximum voltage across

the contacts is 350 V, and the maximum current is 150 mA.

 

 

 

 

This alarm is closed when power is off.

 

 

 

3

Minor Alarm +

The minor alarm output is available for power supply or

4

Minor Alarm -

minor alarm failure alerting. The maximum voltage across

the contacts is 350 V, and the maximum current is 150 mA.

 

 

 

 

This alarm remains open when power is off.

 

 

 

5

Alarm In +

The alarm inputs provide 5 VDC across the two contacts,

6

Alarm In -

and generate an alarm when a short circuit is detected

between the contacts.

 

 

 

 

The alarm generated is a minor severity alarm.

 

 

 