Quick Start

Controller Cards

Controller Cards

T1 Controller Card

Dip Switches

On the front of the T1 Controller card on the Compact T1 are DIP switches used to configure the Compact T1 locally.

Switch

Function

Description

 

ACO

Alarm Cut

0

= Alarm contacts enabled (close when alarm occurs). Default.

 

Off

1

= Alarm contacts disabled (open).

 

 

 

 

 

 

 

ST

Self Test

0

= Normal operation. Default.

 

 

 

1

= Perform Self Test.

 

 

 

 

 

 

 

 

OPT

Spare

 

 

 

 

 

 

 

 

 

 

 

RST

Reset

0

= User-configured operation. Default.

 

 

 

1

= Reset configuration to factory defaults, & reset CLI password

 

 

 

 

 

 

 

T1-1

Line

0

= B8ZS. Default.

 

T2-1

Coding

1

= AMI

 

 

 

 

 

 

 

 

 

T1-2

Line

0

= Loopback off. Default.

T2-2

Loopback

1

= Loopback on

 

 

 

 

 

 

 

 

T1 3-4

Framing

0

= ESF (Extended Superframe). Default.

T2 3-4

 

 

1

= D4

 

 

 

 

 

 

 

 

 

T1 5 - 6

Signaling

 

 

 

 

T2 5 - 6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Switch 3

Switch 4

 

Switch 5

Switch 6

Setting

0

1

 

 

1

1

TR-08 A-Shelf with FDL, 16-bit Alarm

 

 

 

 

 

 

frame

 

 

 

 

 

 

 

1

0

 

 

0

0

TR-08 A-Shelf with FDL, 13-bit Alarm

 

 

 

 

 

 

frame

 

 

 

 

 

 

 

1

0

 

 

0

1

TR-08 A-Shelf with FDL disabled

 

 

 

 

 

 

 

1

0

 

 

1

0

TR-08 B-Shelf

 

 

 

 

 

 

 

0

0

 

 

0

0

Loop Start/Ground Start. Default.

 

 

 

 

 

 

 

0

0

 

 

0

1

E&M Immediate Start with ringback.

 

 

 

 

 

 

(used for D3 PLAR and DPT)

 

 

 

 

 

 

 

0

0

 

 

1

0

E&M Immediate Start with ringback and

 

 

 

 

 

 

Calling Party Disconnect (CPD)

 

 

 

 

 

 

 