Quick Start

Interface Connectors

To connect -48 VDC power:

1.Ensure that no power is present on the two wires to be connected.

2.Strip the two wires from the power source so that approximately 5/16 inch of bare wire is exposed. 16 or 18 AWG insulated copper wire is recommended for power connections.

3.Insert the Battery Return and DC wires into the appropriate square holes, one at a time.

4.Tighten screws to clamp wires.

5.Ensure that no bare wire shows after the wires are installed.

6.Plug connector in the -48 VDC connector, as seen in the graphic and secure with set screws.

7.Apply power to connector from -48 VDC power source.

8.Verify with voltmeter that voltage is correct and polarity is correct.

9.Plug connector in the -48 VDC connector, as seen in the graphic and secure with set screws.

Provided connector (female)

Connector on back of Unit (male)

1(+) 2(-)

Battery Return

-48 VDC

1(+)

2(-)

 

Battery

-48 VDC (-)

Return (+)

 

14

Compact T1 - Release 6.1

Page 18
Image 18
Black Box COMPACT T1 quick start To connect -48 VDC power