When the
When the
Note:
•When "ALC/ELC" is set to "ELC" or "ALC+" (+ page 9),
•If the controller,
4.Gain control setting [AGC]
Select a gain control setting from the following.
ON (HIGH) (default)/ON (MID)/ON (LOW): Automatically increases the gain to make the screen brighter when the illuminance of the subject becomes darker.
HIGH, MID and LOW indicate the gain level. OFF: Does not increase the gain.
Note:
•When "SENS UP" is set to the AUTO mode, “AGC” cannot be set to “OFF”.
5.Electronic sensitivity enhancement setting [SENS UP]
Use of the electronic sensitivity enhancement function increases the quantity of light stored on the CCD, and accordingly the image becomes brighter. The magnification is unchanged for selection of FIX, and the magnification is changeable in accor- dance with the illuminance of a photographic subject for selection of AUTO.
The magnification of the electronic sensitivity is selectable from the following. The setting of the
When the
When the
Note:
•When "ALC/ELC" is set to "ELC" or "ALC+" (+ page 9), or "SHUTTER" is set to "1/100" (+ page 11), only the AUTO mode is enabled.
•When "SHUTTER" is set to "OFF" or other than "1/100", the electronic sensitivity enhancement setting cannot be performed.
•It is impossible to select "AUTO" for "SENS UP" and "1/100" for "SHUTTER" using the following system controller. Use the operation buttons for the setting.
•When the magnification of "SENS UP" is increased, the screen becomes coarser, more whitish, or more flawed. However, this phenomenon is normal.
•If the controller,
6.White balance setting [WHITE BAL]
The white balance adjustment is selectable from the following.
ATW1 (default): Activates the automatic color temperature tracking mode. The camera continuously measures the color tem- perature of the light source and automatically adjusts the white balance. The adjustment of the color temperature ranges from approx. 2 700 K to 6 000 K.
12