Caution!
Improper use may cause unexpected behavior or even cause loss of contact with the unit. If a script does cause problems, reset the unit to its factory default settings (in which case, a backup file may be of use to return the unit to its latest configuration).
Axis strongly recommends that you do not use this function unless you fully understand the consequences. Note that Axis’ support will not assist with customized scripts. For more information, please visit the Developer pages at http://www.axis.com/developer
Plain Config - this function is for the advanced user. All parameters can be set and modified from this page, help is available from the standard help pages.
Resetting to Factory Default Settings
To reset the AXIS 213 to the original default settings, go to the System Options Maintenance web page (described in Maintenance, on page 40) or use the control button on the AXIS 213 as described below:
Using the Control Button
Follow the instructions below to reset the AXIS 213 to factory default settings using the Control Button.
1.Switch off the AXIS 213 by disconnecting the external power supply.
2.Using a suitably pointed object, press and hold the Reset button while you reconnect the power connector.
3.Keep the Reset button pressed for approximately 15 seconds.
4.Release the Reset button.
Note: Resetting to the factory default settings using the Reset Button will cause all parameters (including the IP address) to be reset. Refer to Maintenance, on page 40 for other methods that do not reset the IP address.