AXIS 207/207W - The I/O Terminal Connector 37
The I/O Terminal Connector
Pinout and Interface
The
•1 transistor output
•1 digital input
•auxiliary power and GND
The terminal connector is used in applications for e.g. motion detection, event triggering, time lapse recording, alarm notification via email, image storage to FTP locations, etc.
•Input - for connecting e.g. a pushbutton. If the pushbutton is pressed, the state changes and the input becomes active (shown under Event Configuration > Port Status).
•Output - connects e.g. an alarm device that can be activated by Output buttons on the Live View page, or by an Event Type. The output will show as active (Event Configuration > Port Status) if the alarm device is activated.
Function | Pin | Description | Pinouts |
|
|
|
|
| |
Transistor | 4 | With a maximum load of 100mA and a | The I/O terminal pins on the | |
Output |
| maximum voltage of 24V DC, this output | AXIS 207 and AXIS 207W are | |
|
| has an | numbered as shown below. | |
|
| the emitter connected to the GND pin. If | AXIS 207 |
|
|
| used with an external relay, a diode must be | 4 | |
|
| connected in parallel with the load, for pro- |
| 1 |
|
| tection against voltage transients. |
| |
|
|
| AXIS 207W |
|
Digital Input | 3 | Connect to GND to activate, or leave float- |
| |
|
| |||
|
| ing (or unconnected) to deactivate. | 1 | 4 |
|
|
|
|
|
GND | 1 (AXIS 207W) |
|
|
|
| 2 (AXIS 207) |
|
|
|
|
|
|
|
|
Auxiliary DC | 1 (AXIS 207) | 5VDC/min 2.5W (AXIS 207) |
|
|
Power Input | 2 (AXIS 207W) | 5VDC/min 3.5W (AXIS 207W) |
|
|
| Electrically connected in parallel with the |
|
| |
|
|
|
| |
|
| connector for the |
|
|
|
| this pin provides an auxiliary connector for |
|
|
|
| mains power to the unit. This pin can also |
|
|
|
| be used to power auxiliary equipment, max |
|
|
|
| 50mA. |
|
|
|
|
|
|
|