Silicon Optix CM-525P Connecting Wiring, Connecting RS-485/422, Connecting Video Output Connector

Page 18

2.INSTALLATION / CONFIGURATION

2.2Connecting Wiring

A.CONNECTING RS-485/422

The dome camera can be controlled remotely by an externaI device or control system, such as control keyboard, using RS-485 half duplex, RS-422 duplex or simplex serial communications signaIs. Connect marked RX+, RX- to TX+ and TX- of the RS-485 control system.

If control system is RS-422, connect TX+(TRX+), TX-(TRX-) of the dome camera to TX+, TX- and RX+, RX- of the control device respectively.

B. CONNECTING VIDEO OUTPUT CONNECTOR

Connect the video out (BNC) connector to the monitor or video input.

C. CONNECTING ALARMS

AL1 to 8 (Alarm In)

You can use externaI devices to signaI the dome camera to react to events. Mechanical or electrical switches can be wired to the AL (Alarm In) and GND (Ground) connectors. See Chapter 3 - Program and Operation for Configuring Alarm Input.

Note: All the connectors marked GND are common.

Connect the ground side of the alarm input and/or output to the GND connector.

NC (NO) 1 TO 4 (NormaIly Closed or Normally Open: Alarm Out)

The dome camera can activate external devices such as buzzers or lights. Connect the device to the NC (NO) (Alarm Out) and COM (Common) connectors. See Chapter 3 - Program and Operation for Configuring Alarm Output.

D. CONNECTING THE POWER

Connect the AC 24V 850mA Power Adaptor to the OPTIX dome camera.

18

27104AF

Image 18
Contents Pen Eye Page 27104AF Explanation of Graphical Symbols Compliance Statement CE Compliance StatementImportant Safeguards 27104AF Table of Contents 27104AF Features Power ConsumptionIntroduction 27104AF Package Contents Installation / ConfigurationBasic Installation Part ListBasic Configuration Basic Installation DiagramRemoving Plastic Film Setting UP the Unit for Termination OFFSetting the Camera Address ID Example Termination DiagramSetting UP the DIP Switch NTSC/PALConnecting Video Output Connector Connecting WiringConnecting RS-485/422 Connecting AlarmsGetting Started 27104AF Accessing On-Screen Menu Utility Program & OperationControlling the ON-SCREEN Utility Optix Highspeed Dome Menu 27104AF Folow these steps to program the Home Function PTZ Setup MenuHome HomeSYS Info SYS InfoArea Title Area TitleStartptz Endptz DisplayDisplay Privacy Zone Privacy ZoneOn Screen Display OSD OSD DisplayCooler/Heater Display C H Cooler/Heater On CELSIUS/FAHRENHEIT DisplayView Angle View AnglePosition Horizontal PositionCOOLER/HEATER COOLER/HEATERHOME/PRESET HOME/PRESETDome Setup Pan/Tilt/Zoom 010Dome Setup Auto Scan Auto ScanStartptz Mode Endless Left Coming & GoingMode END PTZTour TourMode & No Tour Setup TOUR1 TOUR2 TOUR8 Speed Fast Freeze OFFPattern PatternAlarms AlarmsFocus FocusWB Control CameraAE Control AE ControlLine Lock Camera Line LockDigital Effect Screen SetupScreen Setup Flickerless On/OffDAY & Night DAY & NightConfig Init DataInit Data Dome Reset Reload IDLanguage Exit Exit27104AF General Technical SpecificationsCamera CM-525P ElectricalDimensions Appendix a Troubleshooting Parapet Wall Swing ARM & Mount Bracket Indoor / Outdoor HousingAppendix B Optional Items Parapet Roof TOP Mount BracketCorner Mount Adaptor Roof Mount AdaptorPole Mount Adaptor Flush Mount Adaptor Wall Mount Adaptor 27104AF 27104AF 27104AF Pen Eye