Figure 7

CV Series amplifier. If your application requires rack mounting, optional line cords, shorter than the standard 2 meter, are available as accessory item for the CV Series amplifiers.

9.Configuration DIP Switches

Each CV Amplifier channel can be individually configured via the DIP Switches on the rear panel. The switches for each channel perform the following functions from left to right: (See figure 7)

Switch 1 - Effects In/Out (up is IN and down is OUT) this switch enables the receive pins (+ and -) on the Effects Loop connector. When using the Effects Loop for outboard signal processing this switch must be in the UP (EFX IN) position.

Note: If the EFX Loop is switched (IN) with no signal present at the

EFX receive inputs, the amplifier will appear to not be working

Switch 2 Clip Limiter (up is ON and down is OFF) The Clip Limiter prevents the

amplifier from being accidentally driven into hard clipping under normal operation. (Note: The Clip Limiter will not protect the amplifier from clipped signals that are introduced at the amplifier input.)

Switch 3 High Pass Filter (up is ON and down is OFF) This switch engages or disengages the internal High Pass filter.

Switch 4 Frequency Selection (up is 120Hz and down is 80Hz) this switch selects the frequency of the High Pass filter. (Note: whenever the High Pass filter is disengaged a 26Hz factory preset high pass filter is engaged)

10.Effects Loop

A four pin Euro Style connector is provided for an unbalanced Effects Loop send and receive. The Input Overload of this feature is set at 20dBu. This Effects Loop can be used to send and receive unbalanced signals from outboard signal processing equipment such as EQ’s, Delays, Limiters and others. For the Effects Loop receive signal, the

EFX IN Switch on the configuration DIP Switch must be set to the (IN or up) position for that channel or zone. The Send pins (+ and -) are always engaged and can be used to loop signal from one amp to another via the receiving amplifiers input module. (Note: The signal at the Send Pins of the Effects Loop are post any signal processing performed by a optional input module that may be in use in the CV Series amplifier). Connections to the Effects Loop are intended to be local, and signals sent over long wire runs are not recommended. Input through the “Input Module” would perform better in this circumstance.

Installation

Location and General Precaution

Observe the following precautions when choosing a location for your amplifier.

A.Do not expose the unit to rain or moisture. If a fluid or foreign object should enter the unit, disconnect the power plug and contact the Carver Professional Service Center. Do not pull out the plug by pulling on the cord; grasp the plug firmly and pull.

B.Protect the amplifier from heat, and allow adequate ventilation. Place away from sources of heat, such as heating vents and radiators. All components produce some heat during operation, so make sure that the ventilation area above and below the heatsink are not covered and that air is allowed to circulate freely around the unit. Excessive heat is the single greatest source of both short-term and long-term component failure.

Mechanical Considerations

When being rack mounted, the CV1501, CV2501, CV1502 and the CV2502 are 2U or 3.5” (89mm) in height, The CV4002 is 3U or 5.25” (133mm) and they are all 17.25” (438mm) in depth inside the rack including the rear supports. Secure the unit to the rack mechanically using four screws. The addition of plastic or rubber washers prevents marring the front panel, but may interfere with grounding.

Rear Support

If the CV Series amplifiers are rack mounted and the rack is to be transported, mechanical support for the rear of the amplifier(s) is required. This could take the form of any mechanical means of tying the

Rev 04.08.021

- 14 –

Image 14
Contents CV Series Safety Information Introduction Important PaperworkCV1501 Specifications with Basic input module Power ConsumptionCV1502 Crosstalk CV4002 Hz to 20 kHz 4 and 8 ohm loads Status LED Display Rack Mount EarsLevel Controls Level Display LEDsStandby LED Power SwitchCV Series Model Number Serial Number Output ConnectorSequence Connector Remote Level XLR ConnectorEuro Connector Standard Input ModuleMechanical Considerations Location and General PrecautionConfiguration DIP Switches Rear SupportThermal Considerations AC Power ConsiderationsInput Wiring Magnetic Leakage ConsiderationMono Operation Input SensitivityLoudspeaker Polarity Class 2 wiring Approved Class 1 Wiring RequiredSequencing Multiple Amplifiers on / OFF Power SequencingTurning a Single Amplifier on / OFF Ground Test Procedure Using Other Amplifiers in the Power Sequence Use of the Remote Level Control ConnectorWiring Requirements for Remote Level Control Applications CV Series Block Diagram Using Third Party Control SystemsWarranty Information Playback Is Mixed with Hum No Sound, No PowerPower On, Low Output or No Output Distortion CV1502 25v tap Power Consumption for CV Series AmplifiersCV2501 25v tap CV2502 25v tapJP100 Bridged, Parallel, Normal SettingsInput Sensitivity