Appendix “B”

Input Sensitivity

Jumpers 101 and 102 on the standard input module’s PCB are used to set the Input Sensitivity of the amplifier for each channel or zone. The output level of the input source determines the setting. Since, each channel or zone may have a different input source, it is acceptable to have these jumpers set differently according to the potential output level of the input source. The figure below show the correct jumper setting for an input sensitivity of 0.775VRMS or 1.5VRMS.

Caution! Before removing the module to change input sensitivity or to set Bridged Mono, Parallel Mono or Normal operating modes, make certain that the amplifier’s AC mains are first switched OFF.

Bridged, Parallel, Normal Settings

Jumper 100 on the standard input module’s PCB is used to configure the Standard Input Module and the amplifier in which it resides to operate in Normal, Bridged Mono or Parallel Mono modes. It is imperative that the module be configured to the operational mode desired before making the loudspeaker connections. Configuration of the jumpers should only be done with the amplifier’s power OFF. The figure below shows the correct jumper placement for each of the three modes of operation.

Bridged Parallel

Mono Mono Normal

JP100

CONFIGURATION

Caution! Before removing the module to change input sensitivity or to set Bridged Mono, Parallel Mono or Normal operating modes, make certain that the amplifier’s AC mains are first switched OFF.

Rev 04.08.021

- 27 –

Image 27
Contents CV Series Safety Information Important Paperwork IntroductionCV1501 Power Consumption Specifications with Basic input moduleCV1502 Crosstalk CV4002 Hz to 20 kHz 4 and 8 ohm loads Level Display LEDs Rack Mount EarsLevel Controls Status LED DisplayPower Switch CV Series Model NumberStandby LED Output Connector Sequence ConnectorSerial Number Standard Input Module XLR ConnectorEuro Connector Remote LevelRear Support Location and General PrecautionConfiguration DIP Switches Mechanical ConsiderationsMagnetic Leakage Consideration AC Power ConsiderationsInput Wiring Thermal ConsiderationsInput Sensitivity Loudspeaker PolarityMono Operation Class 1 Wiring Required Class 2 wiring ApprovedPower Sequencing Turning a Single Amplifier on / OFFSequencing Multiple Amplifiers on / OFF Ground Test Procedure Use of the Remote Level Control Connector Using Other Amplifiers in the Power SequenceWiring Requirements for Remote Level Control Applications Using Third Party Control Systems CV Series Block DiagramWarranty Information No Sound, No Power Power On, Low Output or No OutputPlayback Is Mixed with Hum Distortion CV2502 25v tap Power Consumption for CV Series AmplifiersCV2501 25v tap CV1502 25v tapBridged, Parallel, Normal Settings Input SensitivityJP100