Carver CV Series user manual Hz to 20 kHz 4 and 8 ohm loads

Page 9

SPECIFICATIONS with Basic input module

PERFORMANCE:

THD:

0.5% at rated power, 0.2% at 1/8 rated power at 1kHz

IMD DIM30 Method:

<0.2%

Dynamic Headroom:

1.5dB

Power Bandwidth:

40 Hz to 20 kHz 4 and 8 ohm loads

Frequency Response:26 Hz to 20 kHz +0.5, -3 dB 4 and 8 ohm loads

Signal-to-Noise

94dB (typical), A-Weighted, referred to rated power

Crosstalk:

 

 

-60dB, full bandwidth

CMRR:

 

 

75dB @ 1kHz

Slew Rate:

 

 

7V/µSec

Sensitivity for rated power (includes EFX Inputs):

0dB or 0.775Vrms

Input Impedance (includes EFX Inputs):

 

50kΩ balanced

Input Overload (includes EFX Inputs):

 

20dBu

Protection:

Thermal, Short Circuit, and Over-current & Over Voltage

Stability:

 

Unconditionally stable into reactive loads

Duty Cycle:

 

Continuous operation at 1/3 rated power

POWER REQUIREMENTS:

Mains Voltage (output power rated at nominal voltage): 100VAC, 50-60Hz ±20% 120VAC, 60Hz ±20%

 

230VAC, 50Hz ±20%

Power Consumption

(See Appendix A)

REGULATORY COMPLIANCE:

UL6500, 2nd Edition

Proposed ETL/C Mark to:

CE Certification to:

EN55103-1 & EN55103-2

PHYSICAL:

 

Cooling Method:

Convection

Operating Environment:

-10oC to 55oC, up to 85% RH

Storage Environment:

-45oC to 70oC, up to 93% RH

Dimensions:

5.25” H (2U) x 19.0” W x 17.25” D

 

133mm x 483mm x 438mm

Net Weight:

CV4002 – 54.0lbs. / 24.5kg

Shipping Weight:

CV4002 – 60.0lbs. / 27.3kg

Rev 04.08.021

- 9 –

Image 9
Contents CV Series Safety Information Important Paperwork IntroductionCV1501 Power Consumption Specifications with Basic input moduleCV1502 Crosstalk CV4002 Hz to 20 kHz 4 and 8 ohm loads Level Controls Rack Mount EarsStatus LED Display Level Display LEDsPower Switch CV Series Model NumberStandby LED Output Connector Sequence ConnectorSerial Number Euro Connector XLR ConnectorRemote Level Standard Input ModuleConfiguration DIP Switches Location and General PrecautionMechanical Considerations Rear SupportInput Wiring AC Power ConsiderationsThermal Considerations Magnetic Leakage ConsiderationInput Sensitivity Loudspeaker PolarityMono Operation Class 1 Wiring Required Class 2 wiring ApprovedPower Sequencing Turning a Single Amplifier on / OFFSequencing Multiple Amplifiers on / OFF Ground Test Procedure Use of the Remote Level Control Connector Using Other Amplifiers in the Power SequenceWiring Requirements for Remote Level Control Applications Using Third Party Control Systems CV Series Block DiagramWarranty Information No Sound, No Power Power On, Low Output or No OutputPlayback Is Mixed with Hum Distortion CV2501 25v tap Power Consumption for CV Series AmplifiersCV1502 25v tap CV2502 25v tapBridged, Parallel, Normal Settings Input SensitivityJP100