Carver CV Series user manual CV1502

Page 6

CV1502

Power Output

150W per channel into 4 ohm and 8 ohm loads, autoformer coupled, 40Hz to 20kHz ±3dB with < 0.5% THD at full power

150W per channel, transformer coupled @ 25V, 35V, 50V, 70V and 100V, 40Hz to 18kHz ± 3dB with < 0.5% THD at full power

300W parallel mono at 4 Ohms, 300W parallel and bridged mono at 8 and 16 Ohms, 50V, 70V, 100V, 140V and 200V with no more than 0.5% THD

CV2502

Power Output

250W per channel into 4 ohm and 8 ohm loads, autoformer coupled, 40Hz to 20kHz ±3dB with < 0.5% THD at full power

250W per channel, transformer coupled @ 25V, 35V, 50V, 70V and 100V, 40Hz to 18kHz ± 3dB

500W parallel mono at 4 Ohms, 500W parallel and bridged mono at 8 and 16 Ohms, 50V, 70V, 100V, 140V and 200V with no more than 0.5% THD

Common Features

Convection Cooling

5-segment LED level display, per channel, including signal present and clip indicators

3 LED display, per channel, of Power, Protect and Thermal Overload

Standby LED indicates the amplifier is in Standby Mode

Data LED (used with Computer Control module)

Level controls can be covered with a cap (supplied) to prevent tampering

Remote control of output level via Euro Style connector

Unbalanced Effects Loop (send/receive) via Euro Style Connector

Standard Dual Input Module with line level inputs via Euro Style connectors and XLR jacks, connected in parallel

Switched Clip Limiters

Rev 04.08.021

- 6 –

26Hz High Pass Filters

Switched 80Hz and 120Hz (12db/Octave cut) High Pass Filters

Terminals for Sequencing Power ON/OFF

Speaker Outputs via large gauge Euro Style connectors

Power Switch, 3 positions On, Off, Standby

AC Line Cord (Detachable IEC Type)

Optional Accessories:

Four Input Mixer Module with zone assignment

Paging Modules with variable ducking

Expanded Mic/Line Level Input Module

Computer Control & Monitoring via iON MediaControl Module

DSP control of 28 Band Graphic EQ, 5 Band Parametric EQ, HP Filter, LP Filter, Crossover, Adjustable Limiting and Adjustable Delay via iON MediaDSP Tools Module

Image 6
Contents CV Series Safety Information Introduction Important PaperworkCV1501 Specifications with Basic input module Power ConsumptionCV1502 Crosstalk CV4002 Hz to 20 kHz 4 and 8 ohm loads Status LED Display Rack Mount EarsLevel Controls Level Display LEDsPower Switch CV Series Model NumberStandby LED Output Connector Sequence ConnectorSerial Number Remote Level XLR ConnectorEuro Connector Standard Input ModuleMechanical Considerations Location and General PrecautionConfiguration DIP Switches Rear SupportThermal Considerations AC Power ConsiderationsInput Wiring Magnetic Leakage ConsiderationInput Sensitivity Loudspeaker PolarityMono Operation Class 2 wiring Approved Class 1 Wiring RequiredPower Sequencing Turning a Single Amplifier on / OFFSequencing Multiple Amplifiers on / OFF Ground Test Procedure Using Other Amplifiers in the Power Sequence Use of the Remote Level Control ConnectorWiring Requirements for Remote Level Control Applications CV Series Block Diagram Using Third Party Control SystemsWarranty Information No Sound, No Power Power On, Low Output or No OutputPlayback Is Mixed with Hum Distortion CV1502 25v tap Power Consumption for CV Series AmplifiersCV2501 25v tap CV2502 25v tapBridged, Parallel, Normal Settings Input SensitivityJP100