Carver CV Series user manual Specifications with Basic input module, Power Consumption

Page 5

SPECIFICATIONS with Basic input module

PERFORMANCE:

• THD:

<0.5% @ rated power, 0.2% 1/8 rated power at1 kHz

• IMD DIM30 Method:

 

<0.2%

• Dynamic Headroom:

 

1.5dB

• Power Bandwidth:

 

40 Hz to 20 kHz, 4 and 8 ohm loads

• Frequency Response:

30 Hz to 20 kHz +0.5, -3dB(4 and 8 ohm loads)

• Signal-to-Noise:

94dB (typical), A-weighted, referred to rated power

• CMRR:

 

75dB at 1kHz

• Slew Rate:

 

7V/µSec

• Sensitivity for rated power (includes EFX Inputs):

0dBu or 0.775 Vrms

• Input Impedance (includes EFX Inputs):

50kΩ balanced

• Input Overload (includes EFX Inputs):

20 dBu

•Protection:Thermal, Short Circuit, Over-current & Over Voltage, self-resetting

• Stability:

Unconditionally stable into reactive loads

• Duty Cycle:

Continuous operation with dynamic signal at 1/3rd power

POWER REQUIREMENTS:

• Mains Voltage (output power rated at nominal voltage):

100VAC, 50-60Hz ±20%

 

120VAC, 60Hz ±20%

 

230VAC, 50Hz ±20%

• Power Consumption

(See Appendix A)

REGULATORY COMPLIANCE:

 

• Proposed ETL/C Mark to:

UL6500, 2nd Edition

• CE Certification to:

EN55103-1 & EN55103-2

PHYSICAL:

 

• Cooling Method:

Convection

• Operating Environment:

-10oC to 55oC, up to 85% RH

• Storage Environment:

-45oC to 70oC, up to 93% RH

• Dimensions:

3.5” H (2U) x 19.0” W x 16” D

 

89mm x 483mm x 438mm

• Net Weight:

CV1501 – 27.4lbs / 12.4kg

 

CV2501 – 32.7lbs / 14.9kg

• Shipping Weight:

CV1501 – 32.9lbs. / 15.0kg

 

CV2501 – 38.2lbs. / 17.4kg

Rev 04.08.021

- 5 –

Image 5
Contents CV Series Safety Information Important Paperwork IntroductionCV1501 Power Consumption Specifications with Basic input moduleCV1502 Crosstalk CV4002 Hz to 20 kHz 4 and 8 ohm loads Level Controls Rack Mount EarsStatus LED Display Level Display LEDsStandby LED Power SwitchCV Series Model Number Serial Number Output ConnectorSequence Connector Euro Connector XLR ConnectorRemote Level Standard Input ModuleConfiguration DIP Switches Location and General PrecautionMechanical Considerations Rear SupportInput Wiring AC Power ConsiderationsThermal Considerations Magnetic Leakage ConsiderationMono Operation Input SensitivityLoudspeaker Polarity Class 1 Wiring Required Class 2 wiring ApprovedSequencing Multiple Amplifiers on / OFF Power SequencingTurning a Single Amplifier on / OFF Ground Test Procedure Use of the Remote Level Control Connector Using Other Amplifiers in the Power SequenceWiring Requirements for Remote Level Control Applications Using Third Party Control Systems CV Series Block DiagramWarranty Information Playback Is Mixed with Hum No Sound, No PowerPower On, Low Output or No Output Distortion CV2501 25v tap Power Consumption for CV Series AmplifiersCV1502 25v tap CV2502 25v tapJP100 Bridged, Parallel, Normal SettingsInput Sensitivity