SPECIFICATIONS with Basic input module

PERFORMANCE:

THD:

0.5% at rated power, 0.2% at 1/8 rated power at 1kHz

IMD DIM30 Method:

<0.2%

Dynamic Headroom:

1.5dB

Power Bandwidth:

40 Hz to @20 kHz +0.5, -3 dB

Frequency Response:

26 Hz to 20 kHz, 4 and 8 ohm loads

Signal-to-Noise94dB (typical), A-Weighted, referred to rated power

Crosstalk:

 

 

-60dB, full bandwidth

CMRR:

 

 

75dB at 1kHz

Slew Rate:

 

 

7V/µSec

Sensitivity for rated power (includes EFX Inputs):

0dB or 0.775Vrms

Input Impedance (includes EFX Inputs):

 

50kΩ balanced

Input Overload (includes EFX Inputs):

 

20dBu

Protection:

Thermal, Short Circuit, and Over-current & Over Voltage

Stability:

 

Unconditionally stable into reactive loads

Duty Cycle:

 

Continuous operation at 1/3 rated power

POWER REQUIREMENTS:

Mains Voltage (output power rated at nominal voltage): 100VAC, 50-60Hz ±20% 120VAC, 60Hz ±20%

 

230VAC, 50Hz ±20%

Power Consumption

(See Appendix A)

REGULATORY COMPLIANCE:

UL6500, 2nd Edition

Proposed ETL/C Mark to:

CE Certification to:

EN55103-1 & EN55103-2

PHYSICAL:

 

Cooling Method:

Convection

Operating Environment:

-10oC to 55oC, up to 85% RH

Storage Environment:

-45oC to 70oC, up to 93% RH

Dimensions:

3.5” H (2U) x 19.0” W x 17.25” D

 

89mm x 483mm x 438mm

Net Weight:

CV1502 – 35.1lbs / 15.9kg

 

CV2502 – 42.5lbs / 19.3kg

Shipping Weight:

CV1502 – 41.0lbs. / 18.0kg

 

CV2502 – 48.0lbs. / 22.0kg

Rev 04.08.021

- 7 –

Image 7
Contents CV Series Safety Information Important Paperwork IntroductionCV1501 Power Consumption Specifications with Basic input moduleCV1502 Crosstalk CV4002 Hz to 20 kHz 4 and 8 ohm loads Level Display LEDs Rack Mount EarsLevel Controls Status LED DisplayCV Series Model Number Power SwitchStandby LED Sequence Connector Output ConnectorSerial Number Standard Input Module XLR ConnectorEuro Connector Remote LevelRear Support Location and General PrecautionConfiguration DIP Switches Mechanical ConsiderationsMagnetic Leakage Consideration AC Power ConsiderationsInput Wiring Thermal ConsiderationsLoudspeaker Polarity Input SensitivityMono Operation Class 1 Wiring Required Class 2 wiring ApprovedTurning a Single Amplifier on / OFF Power SequencingSequencing Multiple Amplifiers on / OFF Ground Test Procedure Use of the Remote Level Control Connector Using Other Amplifiers in the Power SequenceWiring Requirements for Remote Level Control Applications Using Third Party Control Systems CV Series Block DiagramWarranty Information Power On, Low Output or No Output No Sound, No PowerPlayback Is Mixed with Hum Distortion CV2502 25v tap Power Consumption for CV Series AmplifiersCV2501 25v tap CV1502 25v tapInput Sensitivity Bridged, Parallel, Normal SettingsJP100