output of the CV2502 to create a Mono 70V output at 500 Watts. Connect the positive (+) lead from the distributed load to the 35V connector on Channel 2, and connect the negative
Caution: A 4 ohm mono load should not be connected to the CV Series amplifier in the bridged mode, but you can use the parallel mono configuration with a 4 ohm load.
The table below lists the recommended “Bridged Mono” connections for a CV Series Dual Channel amplifier using Class 2 Wiring. The user should note that it is possible to bridge the 70 V and 100V terminals, however Class 1 Wiring should be observed. All outputs will be 500 watts on the example amplifier CV2502. (See Table 2 below)
Bridged Mono Connections
(+) |
|
|
| |
CH 1 | CH 2 | Connect to | Bridged Load |
|
4 ohm | 4 ohm | 8 ohm load |
| |
8 ohm | 8 ohm | 16 ohm load | Note! | |
25V | 25V | 50V load | Class 2 wiring Approved | |
35V | 35V | 70V load |
| |
50V | 50V | 100V load |
| |
70v | 70V | 140V load | Note! | |
100V | 100V | 200V load | Class 1 Wiring Required |
Table 2
(+)8 Ohm Mono Load
(+)70V Mono Load
Figure 8
Rev 04.08.021 | - 17 – |