Carver CV Series user manual Class 2 wiring Approved, Class 1 Wiring Required

Page 17

output of the CV2502 to create a Mono 70V output at 500 Watts. Connect the positive (+) lead from the distributed load to the 35V connector on Channel 2, and connect the negative (-) lead from the distributed load to the 35V connector of Channel 1. Be sure that the sum of the output to each of the speakers on the distributed load is less than 500 watts. (See Figure 8) It is also necessary to connect the commons together when bridging a distributed load.

Caution: A 4 ohm mono load should not be connected to the CV Series amplifier in the bridged mode, but you can use the parallel mono configuration with a 4 ohm load.

The table below lists the recommended “Bridged Mono” connections for a CV Series Dual Channel amplifier using Class 2 Wiring. The user should note that it is possible to bridge the 70 V and 100V terminals, however Class 1 Wiring should be observed. All outputs will be 500 watts on the example amplifier CV2502. (See Table 2 below)

Bridged Mono Connections

(-)

(+)

 

 

 

CH 1

CH 2

Connect to

Bridged Load

 

4 ohm

4 ohm

-------------------

8 ohm load

 

8 ohm

8 ohm

-------------------

16 ohm load

Note!

25V

25V

-------------------

50V load

Class 2 wiring Approved

35V

35V

-------------------

70V load

 

50V

50V

-------------------

100V load

 

70v

70V

-------------------

140V load

Note!

100V

100V

-------------------

200V load

Class 1 Wiring Required

Table 2

(+)8 Ohm Mono Load (-)

(+)70V Mono Load (-)

Figure 8

Rev 04.08.021

- 17 –

Image 17
Contents CV Series Safety Information Important Paperwork IntroductionCV1501 Power Consumption Specifications with Basic input moduleCV1502 Crosstalk CV4002 Hz to 20 kHz 4 and 8 ohm loads Level Controls Rack Mount EarsStatus LED Display Level Display LEDsStandby LED Power SwitchCV Series Model Number Serial Number Output ConnectorSequence Connector Euro Connector XLR ConnectorRemote Level Standard Input ModuleConfiguration DIP Switches Location and General PrecautionMechanical Considerations Rear SupportInput Wiring AC Power ConsiderationsThermal Considerations Magnetic Leakage ConsiderationMono Operation Input SensitivityLoudspeaker Polarity Class 1 Wiring Required Class 2 wiring ApprovedSequencing Multiple Amplifiers on / OFF Power SequencingTurning a Single Amplifier on / OFF Ground Test Procedure Use of the Remote Level Control Connector Using Other Amplifiers in the Power SequenceWiring Requirements for Remote Level Control Applications Using Third Party Control Systems CV Series Block DiagramWarranty Information Playback Is Mixed with Hum No Sound, No PowerPower On, Low Output or No Output Distortion CV2501 25v tap Power Consumption for CV Series AmplifiersCV1502 25v tap CV2502 25v tapJP100 Bridged, Parallel, Normal SettingsInput Sensitivity