Peavey PV115D manual IEC Power Cord Connection, 2a Fuse, ON-OFF Switch

Page 17

Second, unscrew the screws holding the clear switch protector on the voltage selector switch (1) just a little, just enough to allow removal of the clear switch protector. The screws DO NOT need to be unscrewed very far.

Third, remove the clear plastic protector from the voltage selector switch.

Fourth, using a small flat blade screwdriver, push the red selector switch slide plate to the other side from where it was. The voltage that is now visible on the red slide plate is the one you have selected.

Fifth, replace the clear plastic protector underneath the two loosened screws, and tighten one down while holding the clear plastic protector in place. Tighten the other screw down, and make sure both screws are tight.

Sixth, the fuse should be changed to the correct amperage rating. For an input power voltage range from 100VAC to 120VAC, use a 6.3 amp rated, 250V 5 x 20 mm cartridge type time-delay fuse, which conforms to the international fuse classification “T6.3AL”. For an input power voltage range of from 220VAC to 240VAC, use a 3.15 amp rated, 250V 5 x 20 mm cartridge type time-delay fuse, which conforms to the international fuse classification “T3.15AL”.

The IEC power cord that is correct for your locale can now be plugged into the IEC receptacle (2), and the Power switch (3) activated to turn on the powered PV®115D speaker system.

2IEC POWER CORD CONNECTION

This receptacle is for the IEC line cord (normally supplied with the correct pins and wiring for your locale) that provides AC power to the unit.

Please read this guide carefully to ensure your personal safety as well as the safety of your equipment.

Never break off the ground pin on any equipment. It is provided for your safety. If the outlet used does not have a ground pin, a suitable grounding adapter should be used and the third wire should be grounded properly. To prevent the risk of shock or fire hazard, always be sure that the mixer and all other associated equipment are properly grounded.

2a FUSE

The unit is AC power line fuse protected from overloads and fault conditions with a slow-blow 5 x 20mm 250V fuse. This fuse is located within the cap of the fuse enclosure just to the left of the ON-OFF switch. If the fuse fails, THE FUSE MUST BE REPLACED WITH THE SAME TYPE AND VALUE IN ORDER TO AVOID DAMAGE TO THE EQUIPMENT AND TO PREVENT VOIDING THE WARRANTY!

The fuse in the PV®115D can be replaced with a time-delay type 5 x 20 mm size 250V rated fuse.

For 100-120VAC operation, a fuse rated at 6.3 amps should be used. In the USA, types GDC, GMC, 215, 218, and 477 cartridge-style 5 x 20 mm size fuses with a 6.3 amp 250V rating can be used.

For 220-240VAC operation, a fuse rated at 3.15 amps and 250V should be used, which conforms to the international fuse classification "T3.15AL".

If the unit continues to blow replacement fuses, do not keep replacing them it should be taken to a qualified service center for repair.

To replace the fuse, be sure to remove the IEC power cord from the IEC socket (2).

Remove the cap to the fuse enclosure (2a) using a flat blade screwdriver tip inserted into the fuse cap slot. Push the cap in and turn the cap CCW and pull the cap out. The blown fuse should come out with the cap. Remove the blown fuse and replace it with the proper type per instructions previously supplied. Then, once the new fuse has been put in place, re-insert the fuse enclosure cap, push in and turn the cap CW, and make sure it is fully seated.

Before re-attaching the IEC power cord to the IEC socket, make sure the Power switch is in the OFF position, so that intermittent contact of the IEC cord while it is being connected will not unduly stress the amplifier or the fuse. Now re-attach the IEC power cord, and you can then use the Power switch to turn the unit on.

3ON-OFF SWITCH

This rocker switch supplies AC power to the PV®115D when switched to the ON position.

17

Image 17
Contents PV115 D Deutsch 人体への電気ショックの危険が考えられる製品筐体内の非絶縁「危険電圧」の存在をユーザーに警告す るものです。 ⁄4 or less Important Safety InstructionsDuration Per Day In Hours Sound Level dBA, Slow Response ⁄ 4 o menos Guarde Estas InstruccionesInstrucciones Importantes Para SU Seguridad Niveau sonore moyen dBA Gardez CES InstructionsInstructions Importantes DE Securite Wichtige Sicherheitshinweise Bewahren SIE Diese Sicherheitshinweise AUFTärkeät Turvallisuusohjeet Säilytä Nämä OhjeetViktiga Säkerhetsinstruktioner Spara Dessa Instruktioner⁄4 o minore 115 Conservate Queste IstruzioniImportanti Norme DI Sicurezza Instruções Importantes DE Segurança Guarde Essas Instruções本書は保管してください 请妥善保管本说明书! ¼ 이하 일별 지속 시간 소음 수준 dBA, 저속 반응Applications FeaturesChanging the Voltage Range of the PV115D Voltage Selector Switch2a Fuse IEC Power Cord ConnectionON-OFF Switch POWER/CLIP LED Contour SwitchSpeaker OUT Jack Input JackLevel Control Adjustment Connecting AC Power To The PV115DConnecting a Signal to the PV115D Use of the PV115D with a powered Subwoofer Using the Speaker OUT jackUSE with a Passive ADD-ON Subwoofer Use of the PV115D with a Speaker StandNo Output at All TroubleshootingHum or Buzz Distorted or Fuzzy SoundCleaning Care and MaintenanceArchitectural and Engineering Specifications Sunlight/HeatElectro-acoustic Crossover Frequency 3 kHz Peavey PV115D SpecificationsPage Page Peavey Electronics Corporation Limited Warranty Customer warranty registration Corporation Electronics Peavey From