Sharp PN-V600 Controlling the Monitor with a PC RS-232C, NCommands for ID control, NID numbers

Page 34

Controlling the Monitor with a PC (RS-232C)

Advanced operation

This section explains commands for daisy chain connection. The basic communication procedure is the same as in the “One-to-one connection with a PC” section.

nCommands for ID control

The command examples shown on this page assume the following connection and ID number set up.

ID number: 1 ID number: 2 ID number: 3 ID number: 4

nID numbers

You can assign a unique ID number to each monitor (see page 24). This allows you to control a particular monitor in a daisy chain of monitors.

You can assign ID numbers either from the menu screen (using the remote control) or from the PC using RS-232 cable.

[Example]

ID number: 1 ID number: 2 ID number: 3 ID number: 4

If monitors are connected as shown above, you can execute commands like “Set the volume of the monitor with ID 4 to 20”.

When designating ID numbers for a set of monitors linked in a daisy chain, you should basically avoid any duplication of ID numbers.

ID numbers do not have to be assigned in ascending order starting from the PC. They can also be connected as shown below.

[Example]

ID number: 3 ID number: 2 ID number: 4 ID number: 1

IDST .........A monitor receiving this command sets its own ID

number in the parameter field.

Example:

IDST0001

OK 001 ← The ID number of this monitor is set to 1.

TIPS

You can automatically assign ID numbers by using the IDST command with the Repeater control (see “Repeater control” on page 35).

For example, using the command “IDST001+” automatically sets the ID numbers, as shown below.

[Example]

ID number: 1 ID number: 2 ID number: 3 ID number: 4

IDST001 +

ID setting command with repeater control

WAIT

 

 

OK

001

“OK” response from ID number: 1

OK

002

“OK” response from ID number: 2

OK

003

“OK” response from ID number: 3

OK

004

“OK” response from ID number: 4 (End)

IDSL ........The parameter of this command sets the ID number

of the monitor. The monitor is subject to the next command.

Example:

IDSL0002

The next command is for the monitor

 

 

 

with ID number: 2.

WAIT

 

Searching for monitor with ID number:

 

 

 

2

OK

002

Found monitor with ID number: 2

VOLM0030

Sets volume of monitor with ID

 

 

 

number: 2 to 30.

WAIT

 

Processing

OK

002

OK response from monitor with ID

 

 

 

number: 2

VOLM0020

Sets volume to 20.

OK

001

 

The volume of the monitor with ID

number: 1 (the one directly connected

to the PC) is set to 20.*

*The IDSL command is effective only once, for the immediately succeeding command.

E34

Image 34
Contents PN-V600 Blue For Customers in U.KGREEN-AND-YELLOW BrownRefer Servicing to Qualified Service Personnel Important InformationEuropean Union Information on Disposal for Users private householdsInformation on Disposal for Business Users Other Countries outside the EUDear Sharp Customer Safety Precautions Rear side buttons Remote control unit buttons Use only the power cord supplied with the monitorFan in this product has a limited lifetime Mounting Precautions Contents Supplied ComponentsNFront view Part NamesNRear view 11 E Connecting Peripheral Equipment Connection when the PN-ZB02 optional is attachedMultiple monitor connection Connecting Peripheral Equipment13 E Connection with video cableConnect the monitors in order Connection with the control kit optionalSet the ID No Installing the batteries Preparing the Remote Control UnitConnecting the Power Cord Remote control operation rangeAffixing the Protection Covers Binding CablesRemoving the Handles Be sure the handles are attached securelyTurning power on/off Turning Power On/OffTurning on the main power Disabling power on/off operationsBasic Operation Input Input mode selectionVOL +/- Volume adjustment MuteBasic Operation 19 EDisplay Dot by Dot Basic Operation NSwitching the screen sizeWide Zoom Normal Cut offThis Monitor only Remote Control Mode21 E Specified MonitorNExample of operation Menu ItemsDisplaying the menu screen NMenu screen displayNSCREEN 23 EMenu item details Menu Items NPICTUREMenu Items NSETUPNAUDIO 25 E Menu Items NOPTION NMULTI 27 EMenu Items NPIP/PbyP NEnlarge Menu Items NDual screen displayPIP 29 E NZOOM2 Special SettingNSCHEDULE NAutomatic adjustment Adjustments for PC screen displayNScreen display for adjustment 31 E PC connection Communication procedureControlling the Monitor with a PC RS-232C Communication conditions33 E NCommunication intervalNID numbers NCommands for ID controlControlling the Monitor with a PC RS-232C Advanced operationVOLM0020 ← 35 ENRepeater control OK 002 IDLK0000 ← Wait ← OK 002 ← VOLM0010 OK 001 ←NSaving the Gamma user data Setting of the Gamma user dataNTo transfer the Gamma user data NActivating the Gamma user dataHow to read the command table RS-232C command tablePower control/Input mode selection 37 EControlling the Monitor with a PC RS-232C Screen menu 39 E Controlling the Monitor with a PC RS-232C Picture menuSetup menu Controlling the Monitor with a PC RS-232C Audio menu41 E Controlling the Monitor with a PC RS-232C Option menuControlling the Monitor with a PC RS-232C Multi menu Image Position Epos settingLandscape orientation Portrait orientation 43 E Initialization/Functional Restriction Setting Function menuControlling the Monitor with a PC RS-232C PIP/PbyP menu Commands for setting of the Gamma user data Controlling the Monitor with a PC RS-232C Others45 E Settings to connect to a LANControlling the Monitor with a PC LAN To set on the monitorDefault Gateway 0.0 Controlling the Monitor with a PC LAN To set from a PCControlling with a PC 47 EControlling the Monitor with a PC LAN Standby mode, Power on is the only operation available Information about this monitor appearsDNS Server User Name / Password49 E Accept IP AddressAccount Name / Password Installation Information NAME/LOCATIONAuthentication Monitor NameCondition 51 ERecipient E-MAIL Addresses ConfirmationTrap Setting of Authentication Error Snmp SettingTrap Setting VersionTroubleshooting 53 ETroubleshooting NPN-ZR01 optional Product Specifications SpecificationsNPN-V600 Product Specifications 55 ENPower management Specifications NDimensional DrawingsNDDC plug and play Specifications NCompatible signal timing PC 57 ESpecifications NCompatible signal timing AV 59 E Mounting Precautions For Sharp dealers and service engineers PN-V600 Me EN11L1
Related manuals
Manual 44 pages 52.15 Kb