JL Audio XD600/6 owner manual My amplifier turns on, but there is no output

Page 17

“My amplifier shuts off once in a while, usually at higher volumes.”

Check your voltage source and grounding point. The power supply of the XD600/6 will operate with charging system voltages down to 10V. Shutdown problems at higher volume levels can occur when the charging system voltage (or remote turn- on voltage) momentarily drops below 10V. These dips can be of very short duration making them extremely difficult to detect with a common DC voltmeter. To ensure proper voltage, inspect all wiring and termination points. It may also be necessary to upgrade the ground wire connecting the battery to the vehicle’s chassis and the power wire connecting the alternator to the battery. Many vehicles employ small (10 AWG - 6 AWG) wire to ground the battery to the vehicle’s chassis and to connect the alternator to the battery. To prevent voltage drops, these wires should  be upgraded to 4 AWG when installing amplifier systems with main fuse ratings above 60A. Grounding problems are the leading cause of misdiagnosed amplifier “failures.”

“My amplifier turns on, but there is no output.”

Check the input signal using an AC voltmeter to measure the voltage from the source unit while an appropriate test tone is played through the source unit (disconnect the input cables from the amplifier prior to this test). The frequency used should be in the range that is to be amplified by the amplifier (example: 50 Hz for a sub bass application or 1 kHz for a full range / high-pass application). A steady, sufficient voltage (between 0.1 and 4.0-volts) should be present at the output of the signal cables.

Check the output of the amplifier. Using the procedure explained in the previous check item (after plugging the input cables back into the amplifier) test for output at the speaker outputs of the amplifier. Remove the speaker wires from the amplifier while doing this to prevent unpleasant noise and possible speaker damage. Turn the volume up approximately half way. 5V AC or more should be measured at the speaker outputs. This output level can vary greatly between amplifiers but it should not be in the millivolt range with the source unit at half volume. If you are reading sufficient voltage, check your speaker connections as explained below.

Check to ensure that the speaker wires are making a good connection with the metal inside the terminal block. The speaker wire connectors are designed to accept up to 8 AWG wire. Make sure to strip the wire to allow for a sufficient connection with the metal inside the terminal block.

ENGLISH

17

Image 17
Contents 600W 3/4/5/6 Channel Amplifier Protect Your Hearing Installation ApplicationsSerial Number Serial NumberSafety Considerations Planning Your InstallationCooling Efficiency Considerations Mounting the amplifier upside down is strongly discouragedSecurely mount the amplifier Product DescriptionMany vehicles employ small 10 AWG Power ConnectionsFuse Requirements Maxi big plastic-body fuses are recommendedTurn-On Lead Input Section Will operate with the Channel 2 signalInput Voltage Range Input Sensitivity ControlsMost speakers are not designed to reproduce Filter ControlsRemote Level control Optional Do not do this Speaker OutputsJL Audio Technical Support Constant Amber yellow IndicatesServicing your JL Audio Amplifier No User Adjustability SYSTEM CONFIGURATIONSBi-AmpLIFIED SYSTEMS Fade Front vs. Rear with no Subwoofer Level ControlNext, turn your attention to the Channel One pair of stereo outputs and dedicated subwoofer outputsIndependent level control of all three channel pairs Necessary Equipment Nine-Step ProcedureAppendix a Dimensions LxWxH Appendix B  Precise Frequency Selection ChartInput Sections Amplifier SectionMy amplifier doesn’t turn on My amplifier turns on, but there is no output INSTALLATION NOTES English If you need service on your JL Audio product Limited Warranty Amplifiers USAJL Audio, Inc International WarrantiesBenutzerhandbuch SeRIENNUMMER Schützen SIE IHR GehörSeriennummer VerwendungsbereichKühlung Planung DER InstallationSicherheitsaspekte FehlervermeidungArbeitsvorgang muss durchgeführt werden Typischer InstallationsablaufProduKtBESCHREIBUNG Zusatzsicherung StromanschlüsseDer XD600/6 benötigt eine herkömmliche EinschaltleitungEingangsempfindlichkeit VerstärkereingängeEingangsspannung Filtereinstellungen Pegelfernbedienung Optional BRÜCKEN-BETRIEB LautsprecherausgängeNur von sehr kurzer Dauer war StatusANZEIGE / SchutzschaltungZWEIWEGe-AKTIV-SYSTEM SYSTEM-KONFIGURATIONENHochpassfilter Keine getrennte Regelung mit dem Steuergerät möglichBeachten Sie dazu Anhang a Seite Benötigte Ausrüstung Anhang aDie Neun-Schritte-Prozedur Drehen Sie den Input Sens. ganz nach links untenAnhang C Anhang B Mein Verstärker schaltet sich nicht ein Anhang D FehlerbehebungDeutsch Installationsnotzizen JL Audio Vertrieb für Deutschland Audio Design GmbH W . j l a u d i o . c o m