6 Controlling the VA-8xl

You can control a single VA-8xlunit (see Section 6.1) or configure up to a 120 channel balanced stereo audio amplifier, using 15 units via RS-485 or RS-232 (see Section 6.3).

6.1Controlling a Single VA-8xl Unit

To connect and control a single VA-8xlunit, connect the following to the rear panel:

PC or other controller, see Section 6.2: “Preparing the RS-232 Port on a Single Unit”

Set the DIP-switches, see Section 6.2.1

Power cord

6.2Preparing the RS-232 Port on a Single Unit

You can connect to the unit via a crossed RS-232 connection, using for example, a PC. A crossed cable or null-modem is required as shown in method A and B respectively. If a shielded cable is used, connect the shield to pin 5.

Method A (Figure 7)—Connect the RS-232 9-pin D-sub port on the unit via a crossed cable (only pin 2 to pin 3, pin 3 to pin 2, and pin 5 to pin 5 need be connected) to the RS-232 9-pin D-sub port on the PC.

Note: There is no need to connect any other pins.

9

5

9

5

4

4

8

8

3

3

7

2

7

2

6

1

6

1

 

 

PC

Figure 7: Crossed Cable RS-232 Connection

Hardware flow control is not required for this unit. In the rare case where a controller requires hardware flow control, short pin 1 to 7 and 8, and pin 4 to 6 on the controller side.

VA-8xl - Controlling the VA-8xl

11

Image 14
Contents VA-8xl Page Figures Introduction Getting Started Achieving the Best PerformanceOverview This section defines the VA-8xlPower Switch VA-8xl 8-Channel Balanced Stereo Audio Amplifier Rear Panel Connecting the VA-8xl If required, connect a PC via RS-232, seeVA-8xl Connecting the VA-8xl Adjusting the Gain/Attenuation of the Channels Operating the VA-8xlStoring and Recalling Setups To store a setting, via the front panel buttonsVA-8xl Operating the VA-8xl Preparing the RS-232 Port on a Single Unit Controlling the VA-8xlControlling a Single VA-8xl Unit To PC Illustrates how to configure up to 15 VA-8xlunits Connecting a Control Interface on a Set of Units Preparing the RS-232 Connectors Connecting the RS-485 Control Interface An RS-485 Control Interface Setup Downloading from the Internet Connecting the PC to the RS-232 PortUpgrading the Flash Memory Upgrading Firmware Splash ScreenOpen Configuration File window appears Atmel Flip Window RS-232 Communication If an error message Not Finished shows, click Run again Atmel Flip Window Operation Completed Technical Specifications Default Communication Parameters RS-232 ProtocolKramer Protocol 1st ByteHex Codes for Attenuation Gain Control Hex Codes for Amplification Gain Control Channel Number CodesVA-8xl Kramer Protocol 2900