Kramer Electronics VA-8xl user manual To PC

Page 15

Method B (Figure 8)—Connect the RS-232 9-pin D-sub port on the unit via a straight (flat) cable to the null-modem adapter, and connect the null-modem adapter to the RS-232 9-pin D-sub port on the PC. The straight cable usually contains all nine wires for a full connection of the D-sub connector. Because the null-modem adapter (which already includes the flow control jumpering described in Method A above) only requires pins 2, 3 and 5 to be connected, you are free to decide whether to connect only these 3 pins or all 9 pins.

9

5

4

8

3

7

2

6

1

 

Null-Modem

Adapter

to PC

Figure 8: Straight Cable RS-232 Connection with a Null Modem Adapter

6.2.1DIP-Switch Settings

Configure the VA-8xlby setting the DIP-switches as defined in Figure 9:

Figure 9: Rear Panel DIP-switches (Factory Default)

DIP #

Function:

1-4

Set the MACHINE # (see Section 6.2.2)

5Not used

6RS-485 termination for first and last machine = ON (RS-485 line terminates with 110Ω); for others = OFF (RS-485 line is open)

7/8

Used for the firmware upgrade procedure (see Section 7)

6.2.2Setting the MACHINE #

To control a unit via RS-232 or RS-485, each unit has to be identified via its unique MACHINE #. Set the MACHINE # on a VA-8xlunit according to the following table. A valid MACHINE # is from 1 to 15.

12

VA-8xl - Controlling the VA-8xl

Image 15
Contents VA-8xl Page Figures Introduction Achieving the Best Performance Getting StartedThis section defines the VA-8xl OverviewPower Switch VA-8xl 8-Channel Balanced Stereo Audio Amplifier Rear Panel If required, connect a PC via RS-232, see Connecting the VA-8xlVA-8xl Connecting the VA-8xl Operating the VA-8xl Adjusting the Gain/Attenuation of the ChannelsTo store a setting, via the front panel buttons Storing and Recalling SetupsVA-8xl Operating the VA-8xl Controlling the VA-8xl Controlling a Single VA-8xl UnitPreparing the RS-232 Port on a Single Unit To PC Illustrates how to configure up to 15 VA-8xlunits Connecting a Control Interface on a Set of Units Preparing the RS-232 Connectors Connecting the RS-485 Control Interface An RS-485 Control Interface Setup Connecting the PC to the RS-232 Port Upgrading the Flash MemoryDownloading from the Internet Splash Screen Upgrading FirmwareOpen Configuration File window appears Atmel Flip Window RS-232 Communication If an error message Not Finished shows, click Run again Atmel Flip Window Operation Completed Technical Specifications RS-232 Protocol Default Communication Parameters1st Byte Kramer ProtocolHex Codes for Attenuation Gain Control Channel Number Codes Hex Codes for Amplification Gain ControlVA-8xl Kramer Protocol 2900