Attendant Monitor Operations Manual | INSTALLATION & CONFIGURATION |
Primary
Configuration
Parameters
From the APM Configuration Entry screen, configure the AttendantMonitor component as follows. All parameters marked with asterisks (*) should be entered exactly as shown. The rest of the entries in the table below are just examples.
Parameter | Entry Value | Description |
|
|
|
Application Name | AttendantMonitor | The name to be displayed in the APM menus. |
|
| This name is displayed as it is entered |
|
| here — i.e., capital letters, lowercase, etc. |
|
|
|
Executable Filename* | /oai/app/attMonitor/ | The path name of the executable file. |
| bin/attMonitor |
|
|
|
|
Group* |
| The group that the component belongs to. |
|
| Make no entry. |
|
|
|
Response Mode* | I(gnore) | The action that the APM is to take with the |
|
| component should a member of the group |
|
| terminate. |
|
|
|
Initialization Batch | N(o) | Whether (Yes or No) the component is to be |
|
| initialized automatically when the OAI system |
|
| is initialized. |
|
|
|
Termination Mode* | M(essage) | How the APM is to notify the component to |
|
| terminate. |
|
|
|
Standard Output | /dev/null | Where any output is sent. |
|
|
|
Number of Restarts | 0 | How many times the APM may restart the |
|
| component after it terminates in error. |
|
|
|
OAI Facilities | Following the instructions in the APM Operations Manual, name the following |
| NEAX2400 facilities for the AttendantMonitor component using the Facilities |
| command on the APM Configuration Entry screen: |
- | SCF | Switch Control |
- | SMFR | Status Request (R) |
- | SMFN | Status Notification (N) |
Continue to the next page for OAI-Conf settings...
Page 9 |