Basic Adjustment of the Polarmount Aerial
System 1 |
|
14/18 V | |
Frequency switching with | 12/0 V |
0/22 kHz | |
|
|
14/18 V, e.g., Grundig package STP 400/STP 300 A, |
|
|
|
|
|
|
|
|
|
|
| |||||
|
| 11/12 |
|
|
|
| ||||||||||
or 0/12 V, e.g., Grundig package STP 300, |
|
|
|
|
|
|
|
|
| |||||||
|
|
|
| GHz |
|
| A | |||||||||
or with 0/22 kHz, e.g., future Astra solution. |
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
| magnetic or |
|
| 910. . .2050MHz | |||||||||
|
|
|
|
|
|
|
|
| polarizer |
|
| |||||
Polarization switching: |
|
|
|
|
|
|
|
| 14/19V 0.5A | |||||||
|
|
|
|
| possible connection for second aerial | B | ||||||||||
exclusively with |
|
|
|
|
| |||||||||||
|
|
|
|
|
|
|
| |||||||||
or magnetic polarizer. |
|
|
|
|
| with control according to sytem 1 or 2. | ON | |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
Frequency |
| Polarization |
| LNC power |
| Preprogrammed |
| Preprogrammed |
|
| Switching | frequency | ||||
|
|
|
|
| ||||||||||||
range |
|
|
|
|
| skew value |
| switching voltage value |
|
|
|
|
|
|
| |
11 GHz |
| V1 (vertical 1) |
| 14 V |
| approx. +30 mA |
| 12 V |
|
| 10 kHz |
|
|
| ||
11 GHz |
| H1 (horizontal 1) |
| 14 V |
| approx. |
| 12 V |
|
| 10 kHz |
|
|
| ||
12 GHz |
| V2 |
| 18 V |
| approx. +18 mA |
| 10 V |
|
| 22 kHz |
|
|
| ||
12 GHZ |
| H2 |
| 18 V |
| approx. |
| 10 V |
|
| 22 kHz |
|
|
|
System 2 |
|
|
|
|
|
|
|
|
|
|
| 12/0 V |
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||
Frequency switching with |
|
|
|
|
|
|
|
| 0/22 kHz |
|
|
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||
0/12 V or |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| 11/12 |
|
|
|
|
|
| |||||||||
0/22 kHz |
|
|
|
|
|
|
|
|
|
| GHz |
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| A |
|
|
| |||||||
Polarization switching with |
|
|
|
|
|
| magnetic | or motor- | driven | 14/19V | 0.5A | ||||||||||||||
|
|
|
|
|
| polarizer or 14/18 V |
|
| |||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 910. . .2050MHz | |||||
14/18 V or |
|
|
|
|
|
|
|
| possible connection for second aerial | B |
|
|
| ||||||||||||
|
|
|
|
|
|
|
| ||||||||||||||||||
|
|
|
|
| with control according to sytem 1 or 2. |
|
|
| ON | ||||||||||||||||
The switching frequency 0/22 kHz can |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
also be used for driving a coaxial relay. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
Frequency |
|
| Polarization |
|
| LNC power |
| Preprogrammed |
|
| Preprogrammed |
|
| Switching | frequency | ||||||||||
|
|
|
|
|
| ||||||||||||||||||||
range |
|
|
|
|
|
|
| skew value |
|
| switching voltage value |
|
|
|
|
|
|
|
|
|
| ||||
11 GHz |
|
| V1 (vertikal 1) |
|
| 14 V |
| approx. +30 mA |
|
| 12 V |
|
| 10 kHz |
|
|
|
|
|
| |||||
11 GHz |
|
| H1 (horizontal 1) |
|
| 18 V |
| approx. |
|
| 12 V |
|
| 10 kHz |
|
|
|
|
|
| |||||
12 GHz |
|
| V2 |
|
| 14 V |
| approx. +18 mA |
|
| 10 V |
|
| 22 kHz |
|
|
|
|
|
| |||||
12 GHZ |
|
| H2 |
|
| 18 V |
| approx. |
|
| 10 V |
|
| 22 kHz |
|
|
|
|
|
| |||||
System 3 |
|
|
|
|
|
| magnetic or |
|
|
|
|
|
|
|
| ||||||||||
|
|
|
|
|
| polarizer or 14/18 V |
|
|
|
|
|
|
|
| |||||||||||
Frequency switching with input A/B for systems with |
|
|
|
|
|
| 11 GHz |
|
|
| |||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||
|
|
|
|
|
|
|
| A |
|
|
| ||||||||||||||
2 LNC´s (A: 11 GHz, B: 12 GHz) and waveguide filter. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| 910. . .2050MHz | ||||||||||||
Polarization switching with |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| 14/19V | 0.5A | ||||||||||
|
|
|
|
|
|
| 12 GHz |
|
|
|
|
|
|
|
| ||||||||||
14/18 V or |
|
|
|
|
|
|
|
|
|
|
|
| B |
|
|
| |||||||||
|
|
|
|
|
|
|
|
| waveguide filter |
|
|
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
| ON | ||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
Frequency |
|
| Polarization |
|
| LNC power |
| Preprogrammed |
|
| Preprogrammed |
|
| Switching frequency | |||||||||||
|
|
|
|
| |||||||||||||||||||||
range |
|
|
|
|
|
|
| skew value |
|
| switching voltage value |
|
|
|
|
|
|
|
|
|
| ||||
11 GHz |
|
| V1 (vertikal 1) |
|
| 14 V |
| approx. +30 mA |
|
| 12 V |
|
| 10 kHz |
|
|
|
|
|
| |||||
11 GHz |
|
| H1 (horizontal 1) |
|
| 18 V |
| approx. |
|
| 12 V |
|
| 10 kHz |
|
|
|
|
|
| |||||
12 GHz |
|
| V2 |
|
| 14 V |
| approx. +18 mA |
|
| 10 V |
|
| 22 kHz |
|
|
|
|
|
| |||||
12 GHZ |
|
| H2 |
|
| 18 V |
| approx. |
|
| 10 V |
|
| 22 kHz |
|
|
|
|
|
|
It is possible to allocate the inputs A/B to sytem 1 or system 2 as desired (make the corresponding adjustments in the installation menu). For system 3, allocation of the inputs A and B is predetermined.
The LNC power 14/18 V and the switching voltage 0/22 kHz are transferred via the coaxial cable which is connected to input A or B. The 0/12 V switching voltage and the control signals for a