Falcon F110 manual Modbus Registers, Register Name Description Units Range

Page 31

A P P E N D I X

MODBUS REGISTERS

Table B.1 Read Output Registers

Register

Name

Description

Units

Range

 

 

 

 

 

40002

FC

Family Code (8 Switch Sensors)

None

0-65535

 

 

 

 

 

40003

SS

Switch Status (8 Switch Sensors)

None

0-65535

 

 

 

 

 

40004

SC

Current Alarm Setting (8 Switch Sensors)

None

0-65535

 

 

 

 

 

40005

AS

Current Alarm State (8 Switch Sensors)

None

0-65535

 

 

 

 

 

 

 

 

 

 

40009

FC

Family Code (External Sensor 1)

None

0-65535

 

 

 

 

 

40010

TC

Current Temperature (External Sensor 1)

Celsius x100

0-65535

 

 

 

 

 

40011

TH

High Temperature (External Sensor 1)

Celsius x100

0-65535

 

 

 

 

 

40012

TL

Low Temperature (External Sensor 1)

Celsius x100

0-65535

 

 

 

 

 

40013

HC

Current Humidity (External Sensor 1)

% Relative Humidity

0-65535

 

 

 

 

 

40014

HH

High Humidity (External Sensor 1)

% Relative Humidity

0-65535

 

 

 

 

 

40015

HL

Low Humidity (External Sensor 1)

% Relative Humidity

0-65535

 

 

 

 

 

 

 

 

 

 

40016

FC

Family Code (External Sensor 2)

None

0-65535

 

 

 

 

 

40017

TC

Current Temperature (External Sensor 2)

Celsius x100

0-65535

 

 

 

 

 

40018

TH

High Temperature (External Sensor 2)

Celsius x100

0-65535

 

 

 

 

 

40019

TL

Low Temperature (External Sensor 2)

Celsius x100

0-65535

 

 

 

 

 

40020

HC

Current Humidity (External Sensor 2)

% Relative Humidity

0-65535

 

 

 

 

 

40021

HH

High Humidity (External Sensor 2)

% Relative Humidity

0-65535

 

 

 

 

 

40022

HL

Low Humidity (External Sensor 2)

% Relative Humidity

0-65535

 

 

 

 

 

 

 

 

 

 

40023

FC

Family Code (External Sensor 3)

None

0-65535

 

 

 

 

 

40024

TC

Current Temperature (External Sensor 3)

Celsius x100

0-65535

 

 

 

 

 

40025

TH

High Temperature (External Sensor 3)

Celsius x100

0-65535

 

 

 

 

 

www.rletech.com

31

970.484.6510

Image 31
Contents Monitoring Revision History Product Registration Rletech.com 970.484.6510 Contents Rletech.com Figures Rletech.com 970.484.6510 Tables Rletech.com Product Description System OverviewFront Panel Front Panel Indicators and ControlsF110 Terminal Block Designations Terminal Block DesignationsSystem Overview 970.484.6510 Getting Started InstallationCommunication IP Address Assignment for Static Only Networks SettingsSearch Set IPUpdate F110 WiringPower Supply Physical Connection 2 RJ45 Ethernet ConnectionF110 Web Interface Overview F110 WEB InterfaceStatus Screen Authentication Security Prompt no Username or Password Settings ScreenNetwork Network SettingsEmail Settings Snmp Snmp SettingsChannel 2, Channel 3 and Channel External Temperature/HumiditySecurity Switched Sensor Alarm ConfigurationAdvanced Security SettingsRestore Defaults Prompt Reset DefaultsAbout Screen Help ScreenTelnet Configuration Modbus Configuration VIA TelnetF110 Modbus Capabilities Enable MODBUS? N? Register Name Description Units Range Modbus RegistersHexadecimal Decimal Value Description Switch Sensor 1 Alarm On 1 = Closed, 0 = Open Modbus Registers 970.484.6510 Inputs Temperature/Humidity Technical SpecificationsOperating Environment Temperature