Falcon F110 manual System Overview, Product Description

Page 11

C H A P T E R

SYSTEM OVERVIEW

1.1.Product Description

The F110 Monitoring System is a comprehensive system which provides equipment protection by monitoring critical operating parameters in enterprises, remote network facilities, communication rooms, and critical support systems. The F110 is a stand alone system. It operates via embedded “firmware” that handles all data collection, alarm reporting, and multiple concurrent communication mediums.

The F110 is designed specifically to monitor any combination of 3 digital temperature/humidity sensors or 3 digital temperature only sensors and up to 8 dry contact sensors (signal quality contacts) that can be distributed at locations spanning up to 100 feet (30m).

Additionally, the F110 allows alert notifications to be sent via email to devices like computers, phones, pagers and PDAs. Users can set up thresholds for temperatures and humidity as well as configure monitoring of Normally Open (N/O) or Normally Closed (N/C) inputs. Status of attached sensors for power, smoke/fire, motion, air flow and more is viewed in real-time. Because each F110 is SNMP enabled, it can easily be monitored by network management software. The F110 can easily be integrated with Building Management Systems (BMS) via the Modbus protocol.

www.rletech.com

11

970.484.6510

Image 11
Contents Monitoring Revision History Product Registration Rletech.com 970.484.6510 Contents Rletech.com Figures Rletech.com 970.484.6510 Tables Rletech.com Product Description System OverviewFront Panel Front Panel Indicators and ControlsF110 Terminal Block Designations Terminal Block DesignationsSystem Overview 970.484.6510 Communication InstallationGetting Started IP Address Assignment for Static Only Networks SettingsSearch Set IPPower Supply F110 WiringUpdate Physical Connection 2 RJ45 Ethernet ConnectionStatus Screen F110 WEB InterfaceF110 Web Interface Overview Authentication Security Prompt no Username or Password Settings ScreenNetwork Network SettingsEmail Settings Snmp Snmp SettingsChannel 2, Channel 3 and Channel External Temperature/HumiditySecurity Switched Sensor Alarm ConfigurationAdvanced Security SettingsRestore Defaults Prompt Reset DefaultsAbout Screen Help ScreenF110 Modbus Capabilities Modbus Configuration VIA TelnetTelnet Configuration Enable MODBUS? N? Register Name Description Units Range Modbus RegistersHexadecimal Decimal Value Description Switch Sensor 1 Alarm On 1 = Closed, 0 = Open Modbus Registers 970.484.6510 Inputs Temperature/Humidity Technical SpecificationsOperating Environment Temperature