6. REMOVING THE MAIN UNIT
English INSTALLATION MANUAL
1.When the rear of the main unit has been secured with the method shown in Figure 6 unfasten the special screw.
2.Remove the outer escutcheon.
3.Insert the hook plate between the spring and the universal mounting bracket, fit tab B of the spring into hole A of the hook plate, then pull the main unit out by the hook plate. (Insert both the right and left edges of the hook plate.) (Figure 9)
Note:
•Keep the hook plate. You cannot remove the main unit without disengaging the hook plate.
Universal mounting bracket | Instrument panel |
| |
| |
| Main |
| Unit |
| Spring |
Outer escutcheon
A B
Figure 9
7. CAUTIONS ON WIRING
1.Be sure to turn the power off before wiring.
2.Be particularly careful where you route the wires.
Keep them well away from the engine, and exhaust pipe, etc. Heat may damage the wires.
3.If the fuse should blow, check to see if the wiring is correct.
If a fuse is blown, replace it with a new one of the same amperage rating as the original (15A FUSE).
4.To replace the fuse, remove the old fuse of the power supply cord and insert the new one. (Figure10)
Note:
•There are various types of fuse holder. Do not let the battery side touch other metal parts.
CAUTION
After the connection, fix the cord by a clamp or insulation tape for protection.
Fuse (15A FUSE)
Fuse holder
Figure 10
74 VRX775VD