4Connections and settings

4.1Connecting inputs

4.1.1DC supply (battery)

Caution

The connection cable must have an in-line fuse. Use the type of fuse shown in the following figure.

Caution

Make sure the unit is grounded.

The Plena Mixer Amplifier has a 24 VDC input (terminal screw). This input can be used in mobile applications, such as boats where 120 or 230 VAC is not available or in applications that must continue to operate in case of a power failure.

When a 24 VDC battery is connected (typically consisting of two 12 VDC lead-acid batteries in series), the unit will operate on the supplied DC voltage.

The Plena Mixer Amplifier has as a built in charger, which charges the connected battery (or batteries if connected in series). A separate battery charger is, therefore, not required. The charger charges the battery with a 0.5 A constant current until the battery voltage reaches 27.4 VDC. The charger then switches over to constant voltage charging (also known as float charging). This means that a battery can be charged at the same rate it is discharging, and thus full capacity battery can be assured.

This type of charging is suited for low duty-cycle applications where a relatively high current or power is infrequently required.

Note

If battery charging is not required, the 0.5 A maximum output current can be used for volume overrides or other purposes instead.

-

 

+

 

FUSE

 

 

 

 

 

 

 

12

VDC

 

-

+

 

 

 

 

 

 

 

 

 

 

 

 

12

VDC

 

 

 

 

figure 4.1: Connecting a DC power supply

Bosch Security Systems 2007-10 PLE-2MA120-US, PLE-2MA240-US en

Image 17
Contents Plena Mixer Amplifier Alerts on the apparatus Important safeguardsPage Thank you for choosing a Bosch Security Systems product Table of contents Operation Introduction Conversion of units of mass Conversion tablesDescription Contents of boxPlena product range Plena Mixer AmplifierSchematic overview of the Plena Mixer Amplifier Plena PLE-WP2Z3S wall panel Controls, connectors and indicatorsFront panel Rear panel Rear panel Intentionally left blank Install unit in rack optional InstallationCheck settings/connections Unpack unitIntentionally left blank DC supply battery Connections and settingsConnecting inputs Priority microphone input Euro connector with triggerAdditional microphones inputs 3 through Secondary microphone inputEmergency inputs Connecting 70 Volt input signalConnecting emergency telephone lines Music source inputs Connecting music source inputsZone 1 Connecting outputsCall only Music onlyConstant voltage loudspeakers Connecting speakersRear panel settings Unit settingsRotary controls Pin settings and labelling Intentionally left blank Switch off Switch on and offSwitch on OperationTone control Microphone/line controlsMusic controls Zone selection Master volume controlOutput controls Intentionally left blank Electrical Technical dataEnvironmental MechanicalPage For more information visit