Bosch Appliances PLE-2MA240-US, PLE-2MA120-US Schematic overview of the Plena Mixer Amplifier

Page 10

Plena Mixer Amplifier Installation and User Instructions Description

en 8

An LED meter monitors the master output before the zone selection. This signal is also present on the headphone connector below the output meter. For total reliability and ease of use, a limiter is integrated into the output stage to restrict output if the user applies too much signal.

The unit has 24 VDC backup input with built in

24 VDC battery charger. A separate battery charger is, therefore, not required. The charger charges the battery with a 0.5 A constant current until the battery voltage reaches 27.4 VDC. The charger then switches over to constant voltage charging (also known as float charging).

Note

When using the unit with backup power of 24 V, make sure that the unit is always powered ON. When the unit is switched OFF, the batteries will be drained as this will be regarded as a power source. Consequently the unit will revert to

24 VDC power from the 24 V input

CALL STATION

 

 

 

 

Call Station Control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

C all O nly

0 0

PTT

0

P hantom

Power

LINE /MIC

LINE /MIC

 

 

 

 

 

 

 

 

 

70 V

 

 

 

 

 

 

 

 

 

 

 

 

Amplifier

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8 Ohm

INS

INS

 

 

 

 

 

 

O ut

In

 

 

 

 

 

 

 

 

 

 

 

C lic k

 

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

s uppressi on

 

 

 

Bal. input

Zone 2

Music only / Line out

0

0

Zone 1

Zone 1

LINE /MIC

LINE /MIC

115 V,2 3 0 V

D.C.supply

CUSL

2 01

Wall Panel input micro controller

figure 2.1: Schematic overview of the Plena Mixer Amplifier

Bosch Security Systems 2007-10 PLE-2MA120-US, PLE-2MA240-US en

Image 10
Contents Plena Mixer Amplifier Important safeguards Alerts on the apparatusPage Thank you for choosing a Bosch Security Systems product Table of contents Operation Introduction Conversion tables Conversion of units of massPlena product range Contents of boxDescription Plena Mixer AmplifierSchematic overview of the Plena Mixer Amplifier Front panel Controls, connectors and indicatorsPlena PLE-WP2Z3S wall panel Rear panel Rear panel Intentionally left blank Check settings/connections InstallationInstall unit in rack optional Unpack unitIntentionally left blank Connecting inputs Connections and settingsDC supply battery Euro connector with trigger Priority microphone inputSecondary microphone input Additional microphones inputs 3 throughConnecting 70 Volt input signal Emergency inputsConnecting emergency telephone lines Connecting music source inputs Music source inputsCall only Connecting outputsZone 1 Music onlyConnecting speakers Constant voltage loudspeakersUnit settings Rear panel settingsRotary controls Pin settings and labelling Intentionally left blank Switch on Switch on and offSwitch off OperationMusic controls Microphone/line controlsTone control Output controls Master volume controlZone selection Intentionally left blank Technical data ElectricalMechanical EnvironmentalPage For more information visit