Kenmore owner manual 153.332040, 153.332050, 153.332060, 153.332070

Page 1

Owner’s Manual

THE ECONOMIZER™ 6 GAS WATER HEATER

POWER VENTED GAS MODELS WITH HOT SURFACE IGNITION

FOR POTABLE WATER HEATING ONLY.

NOT SUITABLE FOR SPACE HEATING.

NOT FOR USE IN MOBILE HOMES.

MODEL NO.

153.332040

40

Gallon Nat

153.332050

50

Gallon Nat

153.332060

40

Gallon LP

153.332070

50

Gallon LP

Safety Instructions

Installation

Operation

Care and Maintenance

Troubleshooting

Parts List

For Your Safety

AN ODORANT IS ADDED TO THE GAS USED BY THIS WATER HEATER.

C3 Technology® Gas Water Heaters meet the new ANSI Z21.10.1 standard that deals with the accidental or unintended ignition of flammable vapors, such as those emitted by gasoline.

ADVERTENCIA

Si no puede leer o entender el inglés y necesita el manual instructivo y/o etiquetas en español puede obtenerlos llamando al 1-800-821-2017. NO TRATE DE INSTALAR O OPERAR ESTE CALENTADOR DE AGUA si no entiende la información en las etiquetas o en el manual instructivo. No hacer caso de esta advertencia podría resultar en la MUERTE O GRAVES LESIONES CORPORALES.

Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A

PRINTED IN THE U.S.A. 0308

www.sears.com

PART NO. 185249-002

Image 1
Contents 153.332050 153.332040153.332060 153.332070Important Definitions Safe INSTALLATION, USE and ServiceSafety Precautions Table of Contents Customer Responsibilities Product SpecificationsKeep Clear of ALL Obstructions Materials and Basic Tools Needed Natural HOT Surface Igniter & Main Burner Typical InstallationPropane HOT Surface Igniter & Main Burner Removing the Old Water Heater Installation InstructionsFacts to Consider about the Location Cause death, serious bodily injury, or property damage Insulation BlanketsALL AIR from Inside Buildings See Hotter Water can Scald Water PipingValve and Pipe Insulation if supplied GAS Piping Sequence of Installation Blower Assembly InstallationSediment Traps Filling the Water HeaterPage Venting and Installation Vent Connections to Blower AssemblyCondensation Maximum Vent LengthsVenting Vent Terminal InstallationVertical Vent Through Roof Vertical Vent Termination RestrictionsRecommended BRUSH* Size for Primer Cement Applications Vent Pipe PreparationStep E Step BStep F Step GOperating Instructions For Your Safety Read Before LightingTemperature Setting Temperature RegulationCondensate Start UP ConditionsSMOKE/ODOR Thermal ExpansionVenting System Inspection Operational ConditionsBurner Operation and Inspection Housekeeping TEMPERATURE-PRESSURE Relief Valve OperationAnode ROD Inspection Service Drain Valve Washer ReplacementDraining Leakage Checkpoints Blower may not start in this LED Status Problem SolutionCondition Blower may run continuouslyTroubleshooting Guidelines Troubleshooting Guidelines This is a Repair Parts LIST, not a Packing List Burner Assembly Outer Door AlternateModel Numbers Part Description Page Page Year Exclusive Kenmore Labor Warranty Year Limited Warranty on Water HeaterWarranty Service Sears Installation Service