TROUBLESHOOTING GUIDELINES
These guidelines should be used by a qualified service agent. Call Sears Service at
for assistance. Inform the associate that this is a “Flammable Vapor Ignition Resistant” Product.
LED STATUS | PROBLEM |
| SOLUTION | |
|
|
| 1 | Ensure the wall outlet (power supply) is properly |
|
| The gas control valve has sensed |
| grounded. |
|
|
| ||
|
|
|
| |
|
| inadequate or no earth ground. | 2 | Ensure all ground connections/wires on the water |
|
|
| ||
|
|
|
| heater are securely connected. |
|
| The gas control valve has sensed | 1 | Ensure the wall outlet/power supply is properly wired. |
|
|
|
| |
|
|
|
| |
|
| reversed polarity in the 120 VAC | 2 | Ensure all internal 120 VAC wiring connections and |
|
| power supply. |
| wiring harness have no reversed wires. 120 VAC "hot" |
|
|
| ||
|
|
|
| wire must connect to the on/off switch. |
|
| Pressure switch circuit remaining |
|
|
|
| closed for more than 5 seconds | 1 | Ensure air pressure switch circuit wiring is correct and |
|
| after heating cycle begins. |
| the air pressure switch is not jumpered. |
|
| Blower may not start in this | 2 | Replace the air pressure switch. |
|
| |||
|
| condition. |
|
|
|
|
| 1 | Ensure the air pressure switch sensing tube is properly |
|
|
|
| connected at both ends and is not kinked or damaged. |
|
|
| 2 | Ensure the correct size of vent and intake air pipe (direct |
|
| Pressure switch circuit remains |
| vent products) was used per the installation instructions |
|
| open longer than 5 seconds after |
| in the manual that came with the water heater. |
|
| the blower is energized. | 3 | Ensure maximum number of elbows or maximum |
|
|
| ||
|
| Blower may run continuously in |
| equivalent feet of vent or intake air pipe has not been |
|
| this condition. |
| exceeded per the installation instructions in the manual |
|
|
|
| that came with the water heater. |
|
|
| 4 | Ensure there are no obstructions in the vent or intake |
|
|
|
| air pipe. |
|
|
| 1 | Check wiring to the hot surface igniter assembly - |
|
|
|
| replace igniter assembly if wiring is damaged or worn. |
|
|
| 2 | Check resistance of the igniter at igniter assembly plug |
|
|
|
| - should be between 11 and 18 ohms - replace igniter if |
|
|
|
| open or shorted. |
|
| The gas control valve has detected | 3 | Check igniter assembly plug and the socket on the |
|
| |||
|
| an open igniter circuit. | ||
|
|
| bottom of the gas control valve for good connection. | |
|
|
|
| |
|
|
| 4 | Replace igniter assembly if the plug is worn or |
|
|
|
| damaged. |
|
|
| 5 | Replace the gas control valve if the igniter assembly |
|
|
|
| socket on the bottom of the control is worn or damaged. |
|
|
| 1 | Gas supply is turned off - pressure is too low. |
|
| Ignition/flame failure. | 2 | Ensure the flame sensor is clean - use fine steel wool |
|
| The gas control valve has reached |
| to clean the flame sensor. |
|
|
|
| |
|
| the maximum number or retries (3) | 3 | Manifold gas pressure to the burner is too low. |
|
| |||
|
| for ignition and is currently locked |
|
|
|
| out for one hour. | 4 | Check igniter assembly plug and the socket on the bottom |
|
| |||
|
|
|
| of the gas control valve for good connection. Replace |
|
| Cycle the power to the water heater |
| igniter assembly if the plug is worn or damaged replace |
|
| off and on to reset. |
| the gas control valve if socket is worn or damaged. |
|
|
| 5 | Replace igniter assembly. |
|
|
|
|
|