Kenmore 153.33207, 153.33204 Operating Instructions, For Your Safety Read Before Lighting

Page 23

OPERATING INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or

 

explosion may result causing property damage, personal injury

 

or loss of life.

FLAMMABLE

BEFORE OPERATING: ENTIRE SYSTEM MUST BE FILLED WITH WATER AND AIR PURGED FROM ALL LINES.

A.This appliance does not have a pilot. It is equipped with an ignitiion device which automatically lights the burner. Do not try to light the burner by hand.

B.BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS: Do not try to light any appliance. Do not touch any electric switch;

do not use any phone in your building.

Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in the gas control but- tons. Never use tools. If the control buttons will not push in, don't try to repair them, call a qualified ser- vice technician. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately contact a qualified installer or service agency to replace a flooded water heater. Do not attempt to repair the unit.

It must be replaced!

OPERATING INSTRUCTIONS

VACATION

 

 

 

WARM

A

B

C VERY

 

 

HOT

COOLER

 

HOTTER

 

--------------

 

-----------------------

----------------------

------------------------------

------------------------------------------------------

 

* -----------------------------------------------------------------------

 

* ----------------------------------------------------------

 

--------------------------------------------------------------------------------------

--------------------------------------------------------------------------------------

* ------------------------------------------------------------------------

 

-----------------------------------------------------------------------------------------------

------------------------------------------------------------------------------------------------------------------------

--------------------------------------------------------

 

1.STOP! Read the safety information above on this label.

2.Set the ON/OFF switch on the control box to the "ON" position.

3.Set the thermostat to the lowest setting by first

pressing the COOLER and HOTTER but- tons together and holding for 1 second. Then press the COOLER button until the Warm indicator light appears.

4.Set the ON/OFF switch on the control box to the "OFF" position.

5.This appliance is equipped with a device which automatically lights the burner.

DO NOT TRY TO LIGHT THE BURNER BY HAND.

6. Wait five (5) minutes to

 

clear out any gas.

 

If you then smell gas,

 

STOP! Follow "B" in

 

the safety information above on this label. If you don't smell gas, go to the next step.

7.Turn on all electrical power to the appliance.

8.Set the ON/OFF switch on the control box to the "ON" postition.

9.Set the thermostat to the desired setting by first

pressing the COOLER and HOTTER but- tons together and holding for 1 second. Then press the HOTTER button

10.WATER TEMPERATURE ADJUSTMENT is approximately 120oF.

CAUTION: Hotter water increases the risk of scald injury. Consult the instruction manual before changing temperature.

11.If the appliance will not operate, follow the instruc- tions "TO TURN OFF GAS TO APPLIANCE" and call your technician or gas supplier.

WARNING: TURN OFF ALL ELECTRIC POWER BEFORE SERVICING.

TO TURN OFF GAS TO APPLIANCE

1.Set the thermostat to the lowest setting by first

pressing the COOLER and HOTTER but- tons together and holding for 1 second. Then press the COOLER button until the Warm indicator light appears.

2.Set the ON/OFF switch on the control box to the "OFF" postition.

3.Turn off all electrical power to the appliance if service is to be performed.

23

Image 23
Contents 153.332070 153.332040153.332050 153.332060Important Definitions Safe INSTALLATION, USE and ServiceSafety Precautions Table of Contents Customer Responsibilities Product SpecificationsKeep Clear of ALL Obstructions Materials and Basic Tools Needed Propane HOT Surface Igniter & Main Burner Typical InstallationNatural HOT Surface Igniter & Main Burner Removing the Old Water Heater Installation InstructionsFacts to Consider about the Location Cause death, serious bodily injury, or property damage Insulation BlanketsALL AIR from Inside Buildings See Hotter Water can Scald Water PipingValve and Pipe Insulation if supplied GAS Piping Filling the Water Heater Blower Assembly InstallationSequence of Installation Sediment TrapsPage Maximum Vent Lengths Vent Connections to Blower AssemblyVenting and Installation CondensationVenting Vent Terminal InstallationVertical Vent Through Roof Vertical Vent Termination RestrictionsRecommended BRUSH* Size for Primer Cement Applications Vent Pipe PreparationStep G Step BStep E Step FOperating Instructions For Your Safety Read Before LightingTemperature Setting Temperature RegulationThermal Expansion Start UP ConditionsCondensate SMOKE/ODORBurner Operation and Inspection Operational ConditionsVenting System Inspection Anode ROD Inspection TEMPERATURE-PRESSURE Relief Valve OperationHousekeeping Draining Drain Valve Washer ReplacementService Leakage Checkpoints Blower may run continuously LED Status Problem SolutionBlower may not start in this ConditionTroubleshooting Guidelines Troubleshooting Guidelines Model Numbers Part Description Burner Assembly Outer Door AlternateThis is a Repair Parts LIST, not a Packing List Page Page Sears Installation Service Year Limited Warranty on Water HeaterYear Exclusive Kenmore Labor Warranty Warranty Service