Kenmore 153.33206, 153.33204, 153.33205 Customer Responsibilities, Product Specifications

Page 5

CUSTOMER RESPONSIBILITIES

Thank You for purchasing a Kenmore water heater. Properly installed and maintained, it should give you years of trouble free service. If you should decide that you want the new water heater professionally installed by Sears call 1-800-4-MY-HOME®. They will arrange for prompt, quality installation by Sears authorized contractors.

Abbreviations Found In This Instruction Manual:

CSA - Canadian Standards Association

ANSI - American National Standards Institute

NFPA - National Fire Protection Association

ASME - American Society of Mechanical Engineers

GAMA - Gas Appliance Manufacturer’s Association

UL - Underwriters Laboratories Inc.

This gas-fired water heater is listed by Underwriters Laboratories Inc. under American National Standard/CSA Standard for Gas Water Heaters ANSI Z21.10.1 • CSA 4.1 (current edition).

PREPARING FOR THE INSTALLATION

1.Read the “Safety Precautions” section, page 3 of this manual first and then the entire manual carefully. If you don’t follow the safety rules, the water heater will not operate properly. It could cause DEATH, SERIOUS BODILY INJURY AND/OR PROPERTY DAMAGE.

This manual contains instructions for the installation, operation, and maintenance of the gas-fired water heater. It also contains warnings throughout the manual that you must read and be aware of. All warnings and all instructions are essential to the proper operation of the water heater and your safety. Since we cannot put everything on the first few pages, READ THE ENTIRE MANUAL

BEFORE ATTEMPTING TO INSTALL OR OPERATE THE WATER HEATER.

2.The installation must conform with these instructions and the local code authority having jurisdiction. In the absence of local codes, installations shall comply with the National Fuel Gas Code ANSI Z223.1/NFPA 54 and the National Electrical Code, NFPA 70. These publications are available from The National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02269.

3.The water heater when installed must be grounded in accordance with the local codes, or in the absence of local codes, the National Electrical Code NFPA 70.

4.If after reading this manual you have any questions or do not understand any portion of the instructions, call the local gas utility or the Sears Service Center.

5.Carefully plan the place where you are going to put the water heater. Correct combustion, vent action, and vent pipe installation are very important in preventing death from possible carbon monoxide poisoning and fires.

Examine the location to ensure the water heater complies with the “Facts to Consider About the Location” section in this manual.

6.For California installation this water heater must be braced, anchored, or strapped to avoid falling or moving during an earthquake. See instructions for correct installation procedures. Instructions may be obtained from California Office of the State Architect, 400 P Street, Sacramento, CA 95814.

7.Massachusetts Code requires this water heater to be installed in accordance with Massachusetts 248-CMR 2.00: State Plumbing Code and 248-CMR 5.00. For more information see next page.

PRODUCT SPECIFICATIONS

 

TANK

 

 

RECOVERY

MINIMUM

 

 

 

CAPACITY

 

INPUT

RATE GALS.

VENT PIPE

DIAMETER

DIMENSIONS IN

MODEL

IN GALS.

TYPE OF

RATE

PER HOUR

INCHES

INCHES

INCHES (mm) HEIGHT

NUMBER

(LTRS)

GAS

(Btu/hr)

@ 90°F RISE

(mm)

(mm)

TO JACKET TOP

153.332040

40 (151)

NATURAL

40,000

44

2 (51)

18 1/2 (470)

55 (1,397)

153.332050

50 (189)

NATURAL

40,000

44

2 (51)

20 (508)

56 3/4 (1,441)

153.332060

40 (151)

PROPANE

40,000

44

2 (51)

18 1/2 (470)

55 (1,397)

153.332070

50 (189)

PROPANE

40,000

44

2 (51)

20 (508)

56 3/4 (1,441)

 

 

 

 

 

 

 

 

5

Image 5
Contents 153.332050 153.332040153.332060 153.332070Important Definitions Safe INSTALLATION, USE and ServiceSafety Precautions Table of Contents Customer Responsibilities Product SpecificationsKeep Clear of ALL Obstructions Materials and Basic Tools Needed Propane HOT Surface Igniter & Main Burner Typical InstallationNatural HOT Surface Igniter & Main Burner Removing the Old Water Heater Installation InstructionsFacts to Consider about the Location Cause death, serious bodily injury, or property damage Insulation BlanketsALL AIR from Inside Buildings See Hotter Water can Scald Water PipingValve and Pipe Insulation if supplied GAS Piping Sequence of Installation Blower Assembly InstallationSediment Traps Filling the Water HeaterPage Venting and Installation Vent Connections to Blower AssemblyCondensation Maximum Vent LengthsVenting Vent Terminal InstallationVertical Vent Through Roof Vertical Vent Termination RestrictionsRecommended BRUSH* Size for Primer Cement Applications Vent Pipe PreparationStep E Step BStep F Step GOperating Instructions For Your Safety Read Before LightingTemperature Setting Temperature RegulationCondensate Start UP ConditionsSMOKE/ODOR Thermal ExpansionBurner Operation and Inspection Operational ConditionsVenting System Inspection Anode ROD Inspection TEMPERATURE-PRESSURE Relief Valve OperationHousekeeping Draining Drain Valve Washer ReplacementService Leakage Checkpoints Blower may not start in this LED Status Problem SolutionCondition Blower may run continuouslyTroubleshooting Guidelines Troubleshooting Guidelines Model Numbers Part Description Burner Assembly Outer Door AlternateThis is a Repair Parts LIST, not a Packing List Page Page Year Exclusive Kenmore Labor Warranty Year Limited Warranty on Water HeaterWarranty Service Sears Installation Service