•MAIN BOARD IC800 M30610MCA-264FP (SYSTEM CONTROLLER)
Pin No. |
| Pin Name | I/O |
|
| Function | |
|
|
|
|
|
| ||
1 |
| JOG1 | I | JOG dial pulse input from the rotary encoder (S713 - AMS ±) | |||
|
|
|
|
|
| ||
2 |
| JOG0 | I | JOG dial pulse input from the rotary encoder (S713 - AMS ±) | |||
3 |
| C1 | O | Monitor output terminal for the test | C1 error rate is output when test mode | ||
|
|
|
|
|
|
| |
4 |
| ADER | O | Monitor output terminal for the test | ADER is output when test mode | ||
|
|
|
|
|
| ||
5 |
| SQSY | I | Subcode Q sync (SCOR) input from the CXD2654R (IC121) | |||
| “L” is input every 13.3 msec | Almost all, “H” is input | |||||
|
|
|
|
| |||
|
|
|
|
|
| ||
6 |
| RMC | I | Remote control signal input from the remote control receiver (IC761) | |||
|
|
|
|
|
| ||
7 |
| AIN1 | I | Sircs remote control signal input of the | |||
|
|
|
|
|
| ||
8 |
| BYTE | I | External data bus line byte selection signal input “L”: 16 bit, “H”: 8 bit (fixed at “L”) | |||
|
|
|
|
|
|
|
|
9 |
| CNVSS | — | Ground terminal |
|
| |
|
|
|
|
|
| ||
10 |
| I | Sub system clock input terminal (32.768 kHz) | ||||
|
|
|
|
|
| ||
11 |
| O | Sub system clock output terminal (32.768 kHz) | ||||
|
|
|
|
|
| ||
12 |
| S.RST | I | System reset signal input from the LA5632 (IC700) “L”: reset | |||
| For several hundreds msec. after the power supply rises, “L” is input, then it changes to “H” | ||||||
|
|
|
|
| |||
|
|
|
|
|
| ||
13 |
| XOUT | O | Main system clock output terminal (7 MHz) | |||
|
|
|
|
|
|
|
|
14 |
| GND | — | Ground terminal |
|
| |
|
|
|
|
|
| ||
15 |
| XIN | I | Main system clock input terminal (7 MHz) | |||
|
|
|
|
|
|
|
|
16 |
| +3.3V | — | Power supply terminal (+3.3V) |
|
| |
|
|
|
|
|
| ||
17 |
| NMI | I | ||||
|
|
|
|
|
| ||
18 |
| DQSY | I | Digital In | |||
| “L” is input every 13.3 msec | Almost all, “H” is input | |||||
|
|
|
|
| |||
|
|
|
|
|
| ||
19 |
| P.DOWN | I | Power down detection signal input terminal “L”: power down, normally: “H” | |||
|
|
|
|
|
| ||
20 |
| XINT | I | Interrupt status input from the CXD2654R (IC121) | |||
|
|
|
|
|
| ||
21 |
| DVOL1 | I | Digital rec level volume input terminal | |||
|
|
|
|
|
| ||
22 |
| DVOL0 | I | Digital rec level volume input terminal | |||
|
|
|
|
|
|
|
|
23 to 30 |
| NC | I | Not used (fixed at “L”) |
|
| |
|
|
|
|
|
| ||
31 |
| SWDT | O | Writing data output to the CXD2654R (IC121) and D/A converter (IC200) | |||
|
|
|
|
|
| ||
32 |
| SRDT | I | Reading data input from the CXD2654R (IC121) | |||
|
|
|
|
|
| ||
33 |
| SCLK | O | Serial clock signal output to the CXD2654R (IC121) and D/A converter (IC200) | |||
|
|
|
|
|
| ||
34 |
| FLCS | O | Chip select signal output to the FL/LED driver (IC771) | |||
|
|
|
|
|
| ||
35 |
| FLDATA | O | Serial data output to the FL/LED driver (IC771) | |||
|
|
|
|
|
|
|
|
36 |
| NC | I | Not used (fixed at “L”) |
|
| |
|
|
|
|
|
| ||
37 |
| FLCLK | O | Serial data transfer clock signal output to the FL/LED driver (IC771) | |||
|
|
|
|
|
|
|
|
38 to 47 |
| NC | I | Not used (fixed at “L”) |
|
| |
|
|
|
|
|
| ||
48 |
| CSET0 | I | Destination setting terminal (US, Canadian models: fixed at “L”, AEP, UK models: fixed at “H”) | |||
|
|
|
|
|
| ||
49 |
| CSET1 | I | Destination setting terminal (US, Canadian models: fixed at “H”, AEP, UK models: fixed at “L”) | |||
|
|
|
|
|
| ||
50 |
| XINSW | I | Setting terminal of the loading control system select (fixed at “H” in this set) | |||
|
|
|
|
|
|
|
|
51 |
| NC | I | Not used (fixed at “L”) |
|
| |
|
|
|
|
|
| ||
52 | MNT2 (XBUSY) | I | Busy signal input from the CXD2654R (IC121) | ||||
|
|
|
|
|
| ||
53 |
|
| O | Reset signal output to the CXD2654R (IC121) and BH6511FS (IC152) “L”: reset | |||
|
|
|
|
|
| ||
54 | MNT1 (SHOCK) | I | Track jump detection signal input from the CXD2654R (IC121) | ||||
|
|
|
|
| |||
55 |
| SENS | I | Internal status (SENSE) input from the CXD2654R (IC121) | |||
|
|
|
|
| |||
56 |
| LDON | O | Laser diode on/off control signal output to the automatic power control circuit “H”: laser on | |||
|
|
|
|
|
| ||
57 |
| REFLECT | I | Detection input from the disc reflection rate detect switch (S102) | |||
| “L”: high reflection rate disc, “H”: low reflection rate disc | ||||||
|
|
|
|
| |||
|
|
|
|
| |||
58 |
| PROTECT | I | ||||
|
|
|
|
|
|
|
|
– 38 –