XR-M510
SECTION 1
SERVICING NOTES
PRECAUTION ON OPEN/CLOSE FRONT PANEL
The front panel opens to the bottom of main unit.
In performing the repair, place the main unit on the base having the height exceeding 1 cm.
front panel
base
1cm
( SIDE VIEW)
Open the front panel by supplying the power through the follow- ing steps:
1.Disconnect the motor connector (CN501) from main board.
2.Supply the power to the motor.
Voltage : 9 V
Yellow wiring : MOTOR –
Black wiring : MOTOR +
black wiring
– yellow wiring
+
MODEL IDENTIFICATION
There are three types of main board in according of destination.
– MAIN Board (Component Side) –
R719
IC601
R720
– MAIN Board (Conductor Side) –
connector (CN501)
R625
R626
| R625 | R626 | R719 | R720 | Indicated language | |
|
|
|
|
|
| |
TYPE A | a | a | ⋅ | ⋅ | English, Spanish, | |
Swedish, Portuguese | ||||||
|
|
|
|
| ||
|
|
|
|
|
| |
TYPE B | ⋅ | ⋅ | a | a | French, German, Dutch, | |
|
|
|
|
| Italian | |
South | a | ⋅ | ⋅ | a | English, Czeck, Polish, | |
European | Turkish | |||||
|
|
|
| |||
|
|
|
|
|
|
TYPE A, B, or South European model can also be identified from the front panel display language.
For a switching method of display language, see page 5.
3