8.Turn the = AMS + knob so that the waveform of the oscilloscope becomes the specified value.
(When the = AMS + knob is turned, the of “EFB-
” changes and the waveform changes.) In this adjustment, waveform varies at intervals of approx. 2%. Adjust the wave- form so that the specified value is satisfied as much as pos- sible.
(Write power traverse adjustment)
(Traverse Waveform)
A
VC
B
Specification A = B
9.Press the [YES] button, and save the adjustment results in the
10.“EFB =
The optical
11.Turn the = AMS + knob until the waveform of the os- cilloscope moves closer to the specified value.
In this adjustment, waveform varies at intervals of approx. 2%. Adjust the waveform so that the specified value is satisfied as much as possible.
(Traverse Waveform)
A
VC
B
Specification A = B
12.Press the [YES] button, and save the adjustment results in the
Next “EF MO ADJUST” is displayed. The disc stops rotating automatically.
13.Press the [ÊÊÊÊÊEJECT]¤ button and take out the disc.
14.Load the check disc (MD)
15.Turn the =AMS + knob and display “EF CD ADJUST” (C12).
16.Press the [YES] button and display “EFB = CD”. Servo is imposed automatically.
17.Turn the = AMS + knob so that the waveform of the oscilloscope moves closer to the specified value.
In this adjustment, waveform varies at intervals of approx. 2%. Adjust the waveform so that the specified value is satisfied as much as possible.
(Traverse Waveform)
A
VC
B
Specification A = B
18.Press the [YES] button, display “EFB = SAV” for a mo- ment and save the adjustment results in the
Next “EF CD ADJUST” will be displayed.
19.Press the [ÊÊÊÊÊEJECT]¤ button and take out the disc.
12.FOCUS BIAS ADJUSTMENT
Adjusting Procedure :
1.Load the
ING CONTINUOUSLY-RECORDED DISC”)
2.Turn the =AMS + knob and display “CPLAY MODE” (C29).
3.Press the [YES] button and display “CPLAY MID”.
4.Press the [MENU/NO] button when “C1 = AD = ” is displayed.
5.Turn the =AMS + knob and display “FBIAS ADJUST” (C13).
6.Press the [YES] button and display “ / a = ”.
The first four digits indicate the C1 error rate, the two digits after [/] indicate ADER, and the 2 digits after [a =] indicate the focus bias value.
7.Turn the =AMS + knob in the clockwise direction and find the focus bias value at which the C1 error rate becomes about 200 (Refer to Note 2).
8.Press the [YES] button and display “ / b = ”.
9.Turn the = AMS + knob in the counterclockwise di- rection and find the focus bias value at which the C1 error rate becomes about 200.
10.Press the [YES] button and display “ / c = ”.
11.Check that the C1 error rate is below 50 and ADER is 00. Then press the [YES] button.
12.If the “( )” in “ - - ()” is above 20, press the [YES] button.
If below 20, press the [MENU/NO] button and repeat the ad- justment from step 2.
13.Press the [ÊÊÊÊÊEJECT]¤ button and take out the disc.
Note 1: The relation between the C1 error and focus bias is as shown in the following figure. Find points A and B in the following figure using the above adjustment. The focal point position C is auto- matically calculated from points A and B.
Note 2: As the C1 error rate changes, perform the adjustment using the average vale.
C1 error
about 200
B | C | A | Focus bias value |
|
|
| (F. BIAS) |