
• Description of Indication History
History code number | Description |
|
|
1st0 | The first error |
1st1 | Total recording time when 1st0 was generated (Higher rank byte) |
|
|
1st2 | Total recording time when 1st0 was generated (Lower rank byte) |
N 0 | The last error |
|
|
N 1 | Total recording time when N 0 was generated (Higher rank byte) |
|
|
N 2 | Total recording time when N 0 was generated (Lower rank byte) |
|
|
One error before the last. | |
|
|
Total recording time when | |
|
|
Total recording time when | |
Two errors before the last. | |
|
|
Total recording time when | |
Total recording time when | |
|
|
REC | Total recording time * |
* Total recording time
Total recording time is recorded in minutes. It is recorded in hexadecimal format and up to 65,535 min. can be counted. It returns to “0000h” when recorder goes beyond this limit.
• Description of Error Indication Codes
Problem | Indication code | Meaning of code | Description |
|
|
|
|
No error | 00 | No error |
|
| 01 | Illegal access target address | Attempt to access an abnormal address |
| was specified |
| |
|
|
| |
|
|
|
|
Servo error | 02 | High temperture | High temperture |
| 03 | Focus error | Forcus could not be applied |
|
|
|
|
| 04 | Spindle error | Abnormal lotation of disc |
Power error | 22 | Low battery | Momentary interruption detected |
1.Setting the test mode. (See page 13.)
2.Move up the jog key on the set or press the [DISPLAY] key on the remote commander activates the
3.Press the X key or [REC] key on the set during display of