Sony MZ-R900 Section Test Mode, Outline, Setting Method of Test Mode, Releasing the Test Mode

Page 12

MZ-R900

SECTION 4

TEST MODE

Outline

This set provides the Overall adjustment mode that allows CD and MO discs to be automatically adjusted when in the test mode. In this overall adjustment mode, the disc is discriminate between CD and MO, and each adjustment is automatically executed in order. If a fault is found, the system displays its location. Also, the manual mode allows each individual adjustment to be auto- matically adjusted.

Operation in the test mode is performed with the set. A key having no particular description in the text, indicates a set key.

For the LCD display, the LCD on the remote commander is shown, but the contents of LCD display on the set are same.

Setting Method of Test Mode

There are two different methods to set the test mode:

1Short SL801 (TEST) on the MAIN board with a solder bridge (connect pin 3 of IC801 to the ground). Then, turn on the

power.

– MAIN Board (Conductor Side) –

3

79

77

70

81

60

58

 

 

 

0

74

67

65

63

62

57

61

 

 

31 133 135 137

68

55

54

56

 

 

4

76

73

66

 

59

49

53

+

C830

 

 

 

 

 

44

50

47

 

 

 

 

 

 

 

 

 

 

 

 

35

36

45

 

 

 

 

 

 

 

31

30

51

L801

 

 

 

 

 

113

24

42

 

 

 

IC801

 

 

25

20

26

 

C809

 

 

 

28

16

40

 

 

 

 

 

 

 

 

 

 

 

 

 

23

17

38

 

+

 

 

 

 

 

 

 

 

 

 

 

 

21

15

34

C813

 

 

 

 

 

 

27

8

22

 

 

 

 

 

 

96

95

18

C801

SL801

 

 

 

 

 

19

4

9

 

 

 

 

 

29

2

7

(TEST)

 

 

 

 

 

 

 

 

 

 

 

6

1

3

 

 

 

 

 

 

48

10

5

 

 

 

 

 

 

 

241

12

11

 

 

Operation in Setting the Test Mode

When the test mode becomes active, first the display check mode is selected.

Other mode can be selected from the display check mode.

When the test mode is set, the LCD repeats the following dis- play.

Remote commander LCD display

All lit

888

BASS12

All off

 

 

Microcomputer

version 003 V1.000 display

Destination code

002 : Except US, Canadian models

003 : US, Canadian models

When the X key is pressed and hold down, the display at that time is held so that display can be checked.

Caution: On the set having the microcomputer version 1.000, some adjusted values were set in the manual mode at the shipment, but these data will be cleared when the NV is reset. Therefore, on the set having the micro- computer version 1.000, change the adjusted values following the Change of Adjusted Values immediately after the NV was reset (see page 17).

Releasing the Test Mode

For test mode set with the method 1:

Turn off the power and open the solder bridge on SL801 (TEST) on the MAIN board.

Note: Remove the solders completely. Remaining could be shorted with the chassis, etc.

For test mode set with the method 2:

Turn off the power.

Note: If electrical adjustment (see page 17) has not been finished com- pletely, always start in the test mode. (The set cannot start in nor- mal mode)

2In the normal mode, turn on the [HOLD] switch. While press- ing the [VOL --]key press the following order:

>t > t . t . t > t

. t > t . t X t X

12

Image 12
Contents Specifications Battery life1927-991-13 Table of Contents DisassemblyDiagrams Exploded ViewsFlexible Circuit Board Repairing Section Servicing NotesSection General Looking at controlsSection Disassembly Disassembly FlowPanel ASSY, Bottom Panel ASSY, Upper Section LCD MODULE, Panel ASSY, UpperCase ASSY, BATTERY, Main Board Main Board AssySTRIP, Ornamental MD Mechanism Deck MT-MZR900-171, Chassis ASSY, SETService ASSY, OP LCX-4R Holder Assy Motor Flexible BoardMOTOR, DC Sled M602 Section Test Mode Setting Method of Test ModeOperation in Setting the Test Mode Releasing the Test ModeConfiguration of Test Mode Manual ModeTransition method in Manual Mode A n u a l011 C 6 8 S 0 F F J 0011 0 6 3 B 0 0XX 1 0 0 0Reset the error display code Description of Error Indication CodesSetting method of Reset the Error Display Code Description of Indication History000 P * * R 000000 FF RPLAYReset ResNV CCResOK? 021 Res871 V5num 872 V5datAssy00 762 Vc1PWMADJ OK SetTmpHrefPw WritPwAssy Assy11Ofst OfstOKAdjustment Method of Overall CD and MO Adjustment Mode Overall CD and MO adjustment items000 *** NG CD OKResume CC 043 ResResClr PatClr CC023 0D6000 023 0D6008023 0D6100 023 0D61A1023 0D5DAA 023 0D5E04023 0D6120 023 0D6400023 0D6909 023 0D6C00023 0D6CF6 023 0D6D00023 0D751C 023 0D7600023 0D7603 023 0D7800Diagrams Block Diagram Servo SectionSection Block Diagram Audio Section Block Diagram KEY CONTROL/DISPLAY/POWER Supply Section Waveforms Vp-pPrinted Wiring Boards Semiconductor LocationMZ-R900 IC Block Diagrams IC301 AK4562VNS-LXPC18A22FCR2 IC PIN Function Description Pause KEY MIC SenseXtest MIFVSS3Adio AVD2AVS2 AdrbDSPVDD2 DSPVSS1Spcu SpcvTEST1, TEST0 EVASSB Data SSB CLKXPD ADA XCS LCDLCD STB LCD RSTSection Exploded Views Panel SectionChassis Section MT-MZR900-171 Not suppliedMD Mechanism Deck Section MT-MZR900-171 Main Electrical Parts List SemiconductorsConnector MainXPC18A22FCR2 RES-CHIP CASE, Battery Charge Except JEW Memo Revision History