MZ-R900
• Description of Error Indication Codes
Problem |
| Indication code |
| Meaning of code | Simple display | Description | ||
|
|
|
|
|
|
| ||
No error |
| 00 |
| No error | No error | |||
|
|
|
|
|
|
|
| |
|
|
| 01 |
| Illegal access target | Adrs | Attempt to access an abnormal address | |
|
|
|
| address was specified | ||||
|
|
|
|
|
|
| ||
|
|
|
|
|
|
| ||
Servo system error |
| 02 |
| High temperature | Temp | High temperature | ||
|
|
|
|
|
|
|
| |
|
|
| 03 |
| Focus error | Fcus | Disordered focus | |
|
|
|
|
|
|
|
| |
|
|
| 04 |
| Spindle error | Spdl | Abnormal rotation of disc | |
|
|
|
|
|
|
|
| |
TOC error |
| 11 |
| TOC error | TOC | Faulty TOC contents | ||
|
|
|
|
|
|
| ||
| 12 |
| Data reading error | Data | Data could not be read at SYNC | |||
|
|
|
| |||||
|
|
|
|
|
|
| ||
Power supply system error |
| 22 |
| Low battery | LBat | Momentary interruption detected | ||
|
|
| 31 |
| Offset error | Ofst | Offset error | |
|
|
| 32 |
| Focus error ABCD | ABCD | Focus error ABCD offset error | |
|
|
|
| offset error | ||||
|
|
|
|
|
|
| ||
|
|
|
|
|
|
| ||
Offset system error |
| 33 |
| Tracking error | TE | Tracking error Offset error | ||
|
|
|
| Offset error | ||||
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| |
|
|
| 34 |
| X1 tracking error | X1TE | X1 tracking error Offset error | |
|
|
|
| Offset error | ||||
|
|
|
|
|
|
| ||
• Description of Indication History |
|
|
|
| ||||
|
|
|
|
|
|
| ||
History code number |
|
| Description |
|
|
| ||
1 |
| The first error |
|
|
|
| ||
N |
| The last error |
|
|
|
| ||
N1 |
| One error before the last. |
|
|
| |||
|
|
|
|
|
|
|
| |
N2 |
| Two errors before the last. |
|
|
| |||
|
|
|
|
|
|
|
|
|
R_ |
| Total recording time |
|
|
|
| ||
|
|
|
|
|
|
|
|
|
Reset the error display code
After servicing, reset the error display code.
•Setting method of Reset the Error Display Code
1. Setting the test mode (see page 12).
2. Press the [JOG LEVER $L% R] (up) key or [DISPLAY] key on the remote commander activates the
3. To reset the error display code, press the X key (2 times) when the code is displayed (except “R_****”).
(All the data on the 1, N, N1, and N2 will be reset)