MZ-R900
Resume Clear
Perform the Resume clear when all adjustments completed.
• Resume Clear Setting Method
1.Select the manual mode of the test mode, and set item number 043 (see page 13).
Remote commander LCD display
043 Resume CC
2. Press the X key.
Remote commander LCD display
043Res***
Resume clear complete
043ResClr
3.Press the x key to return to the test mode (display check mode).
Patch Data Rewriting When Nonvolatile Memory was Replaced
On this set, if the nonvolatile memory was replaced, the modified program data must be written to the nonvolatile memory.
In such a case, write the modified data that meets the microcomputer version following the procedure provided below.
• Modified Data Writing Method (version 1.000)
1.Select the manual mode of the test mode, and set item number 022 (see page 13).
Remote commander LCD display
022 PatClr CC
2.Press the X key to initialize the patch data.
(The modified data writing is over, if the adjusted value changes to DD)
Remote commander LCD display
022***SDD
DD:Adjusted value
3.Press the N key or > key to set item number 023.
Remote commander LCD display
023Patch00
00:Adjusted value
4.Press the [VOL+] key once to change the adjusted value to 01.
5.Press the [DISPLAY] key on the remote commander for several seconds (about 3 seconds) to activate the patch data write mode. (The following display will appear where 00 is blinking)
Remote commander LCD display
0230D5800
00:Adjusted value
6.Adjust with the [VOL+] key (adjusted value up) or
Remote commander LCD display
0230D581E
1E:Adjusted value
7.Press the X key.
(0D58 is blinking)
Remote commander LCD display
0230D581E
1E:Adjusted value
8.Press the [VOL+] key once to change the blinking portion to 0D59.
Remote commander LCD display
0230D5900
00:Adjusted value
9.Press the x key.
(00 is blinking)
10.Adjust with the [VOL+] key (adjusted value up) or
Remote commander LCD display
0230D59B2
B2:Adjusted value
11.Press the X key.
(0D59 is blinking)
12.Press the [VOL+] key once to change the blinking portion to 0D5E.
Remote commander LCD display
0230D5E00
00:Adjusted value
13.Press the x key.
(00 is blinking)
14.Adjust with the [VOL+] key (adjusted value up) or
Remote commander LCD display
0230D5E8B
8B:Adjusted value
15.Press the X key. (0D5E is blinking)
16.Press the [VOL+] key once to change the blinking portion to 0D5F.
Remote commander LCD display
0230D5F00
00:Adjusted value
17.Press the x key.
(00 is blinking)
18.Adjust with the [VOL+] key (adjusted value up) or
Remote commander LCD display
0230D5F20
20:Adjusted value
19.Press the X key. (0D5F is blinking)
22