RS-232C Specifications and Commands
Computer control
A computer can be used to control the projector by connecting an
Communication conditions
Set the serial port settings of the computer to match that of the table.
Signal format: Conforms to | Parity bit: None |
Baud rate*: 9,600 bps / 115,200 bps | Stop bit: 1 bit |
Data length: 8 bits | Flow control: None |
*Set the projector’s baud rate to the same rate as used by the computer.
Basic format
Commands from the computer are sent in the following order: command, parameter, and return code. After the projector processes the command from the computer, it sends a response code to the computer.
Command format
C1 C2 C3 C4 P1 P2 P3 P4
Return code (0DH)
Command | Parameter |
Response code format Normal response
O K
Return code (0DH)
Problem response (communication error or incorrect command)
E | R | R |
| Return code (0DH) |
|
|
|
|
|
Info
•When controlling the projector using
•After sending an input selection or picture adjustment command and then receiving an “OK” response code, the projector may take some time to process the command. If a second command is sent while the projector is still processing the first command, you may receive an “ERR” response code. If this happens, try resending the second command.
•When more than one code is being sent, send each command only after the response code for the previ- ous command from the projector is verified.
•“POWR????” “TABN _ _ _ 1” “TLPS _ _ _ 1” “TPOW _ _ _ 1” “TLPN _ _ _ 1” “TLTT _ _ _ 1” “TLTL _ _ _ 1” “TNAM _ _ _ 1” “MNRD _ _ _ 1” “PJN0 _ _ _ 1”
−When the projector receives the special commands shown above:
*The
*The “Auto Power Off” timer will not be reset.
−The special commands are available for applications that require continuous polling.
Note
•If an underbar (_) appears in the parameter column, enter a space.
•If an asterisk (*) appears in the parameter column, enter a value in the range indicated in brackets under
Control Contents.
*1 For setting the projector name, send the commands in the order of PJN1, PJN2 and PJN3.
*2 This command should be sent only after the “IRGB _ _ _ 2” command is sent and an “OK” response code is received.
*3 The Lamp Timer Reset command is available only in standby mode.