4-5. SELECTING THE TEST MODE
There are 31 types of test modes as shown below. The groups can be switched by rotating the
Refer to “Group” in the table for details selected.
All items used for servicing can be treated using group S. So be carefully not to enter other groups by mistake.
Display | Contents | Mark |
| Group (*) |
| |
|
|
|
|
|
|
|
TEMP CHECK | Temperature compensation offset check |
| C |
| S |
|
|
|
|
|
|
|
|
LDPWR CHECK | Laser power check |
| C |
| S |
|
|
|
|
|
|
|
|
EF MO CHECK | Traverse (MO) check |
| C |
| S |
|
|
|
|
|
|
|
|
EF CD CHECK | Traverse (CD) check |
| C |
| S |
|
|
|
|
|
|
|
|
FBIAS CHECK | Focus bias check |
| C |
| S |
|
|
|
|
|
|
|
|
S curve CHECK | S letter check | (X) | C |
|
|
|
|
|
|
|
|
|
|
VERIFY MODE | (X) | C |
|
|
| |
|
|
|
|
|
|
|
DETRK CHECK | Detrack check | (X) | C |
|
|
|
|
|
|
|
|
|
|
TEMP ADJUST | Temperature compensation offset adjustment |
|
| A | S |
|
|
|
|
|
|
|
|
LDPWR ADJUST | Laser power adjustment |
|
| A | S |
|
|
|
|
|
|
|
|
EF MO ADJUST | Traverse (MO) adjustment |
|
| A | S |
|
|
|
|
|
|
|
|
EF CD ADJUST | Traverse (CD) adjustment |
|
| A | S |
|
|
|
|
|
|
|
|
FBIAS ADJUST | Focus bias adjustment |
|
| A | S |
|
|
|
|
|
|
|
|
EEP MODE | (X) (!) |
|
|
| D | |
|
|
|
|
|
|
|
MANUAL CMD | Command transmission | (X) |
|
|
| D |
|
|
|
|
|
|
|
SVDATA READ | Status display | (X) |
|
|
| D |
|
|
|
|
|
|
|
ERR DP MODE | Error history display, clear |
|
|
| S |
|
|
|
|
|
|
|
|
SLES MOVE | Sled check | (X) |
|
|
| D |
|
|
|
|
|
|
|
ACCESS MODE | Access check | (X) |
|
|
| D |
|
|
|
|
|
|
|
0920 CHECK | Outermost circumference check | (X) |
|
|
| D |
|
|
|
|
|
|
|
HEAD ADJUST | Head position check | (X) |
|
|
| D |
|
|
|
|
|
|
|
CPLAY2 MODE | Same functions as CPLAY MODE | (X) |
|
|
| D |
|
|
|
|
|
|
|
CREC2 MODE | Same functions as CREC MODE | (X) |
|
|
| D |
|
|
|
|
|
|
|
ADJ CLEAR | Initialization of |
|
| A | S |
|
|
|
|
|
|
|
|
AG Set (MO) | Auto gain output level adjustment (MO) |
|
| A | S |
|
|
|
|
|
|
|
|
AG Set (CD) | Auto gain output level adjustment (CD) |
|
| A | S |
|
|
|
|
|
|
|
|
Iop Read | IOP data display |
| C |
| S |
|
|
|
|
|
|
|
|
Iop Write | IOP data write |
|
| A | S |
|
|
|
|
|
|
|
|
INFOMATION | Microprocessing version display |
| C |
| S |
|
|
|
|
|
|
|
|
CPLAY MODE | Continuous play mode |
| C | A | S | D |
|
|
|
|
|
|
|
CREC MODE | Continuous recording mode |
| C | A | S | D |
|
|
|
|
|
|
|
Group (*) |
|
C: Check | A: Adjust |
S: Service | D: Develop |
• For details of each adjustment mode, refer to “5. Electrical Adjustments”.
For details of “ERR DP MODE”, refer to
•If a different mode has been selected by mistake, press the MENU/NO button to exit that mode.
•Modes with (X) in the Mark column are not used for servicing and therefore are not described in detail. If these modes are set accidentally, press the MENU/NO button to exit the mode immediately. Be especially careful not to set the modes with (!) as they will overwrite the
– 20 –