5-7. INITIAL SETTING OF ADJUSTMENT VALUE

Note:

Mode which sets the adjustment results recorded in the non-volatile memory to the initial setting value. However the results of the temperature compensation offset adjustment will not change to the initial setting value.

If initial setting is performed, perform all adjustments again excluding the temperature compensation offset adjustment.

For details of the initial setting, refer to “5-4. Precautions on Adjustments” and execute the initial setting before the adjustment as required.

Setting Procedure :

1.Rotate the ˜+ knob to display “ADJ CLEAR”.

2.Press the ENTER/YES button. “Complete!” will be displayed momentarily and initial setting will be executed, after which “ADJ CLEAR” will be displayed.

5-8. RECORDING AND DISPLAYING THE IOP INFORMATION

The IOP data can be recorded in the non-volatile memory. The IOP value on the label of the optical pickup and the IOP value after the adjustment will be recorded. Recording these data eliminates the need to read the label on the optical pick-up.

Recording Procedure :

1.While pressing the ENTER/YES button and π button, con- nect the power plug to the outlet, and release the ENTER/YES button and π button.

2.“TEMP CHECK” will be displayed. Press the MENU/NO but- ton to display “Check”.

3.Rotate the ˜+ knob to display “[Service]”, and press the ENTER/YES button.

4.Rotate the ˜+ knob to display “Iop.Write”, and press the ENTER/YES button.

5.The display becomes Ref=@@@.@ (@ is an arbitrary number) and the numbers which can be changed will blink.

6.Input the IOP value written on the optical pick-up. To select the number : Rotate the ˜+ knob.

To select the digit : Press the CD SYNC/MD WM SYNC but- ton.

7.When the ENTER/YES button is pressed, the display becomes “Measu=@@@.@” (@ is an arbitrary number).

8.As the adjustment results are recorded for the step 7 value. Leave it as it is and press the ENTER/YES button.

9.“Complete!” will be displayed momentarily. The value will be recorded in the non-volatile memory and the display will become “Iop Write”.

Display Procedure :

1.Rotate the ˜+ knob to display “Iop.Read”.

2.“@@.@/##.#” is displayed and the recorded contents are displayed.

@@.@ indicates the Iop value labeled on the pick-up.

##.# indicates the Iop value after adjustment

3.To end, press the CD SYNC/MD WM SYNC button. or MENU/ NO button to display “Iop Read”.

5-9. TEMPERATURE COMPENSATION OFFSET ADJUTMENT

Save the temperature data at that time in the non-volatile memory as 25 ˚C reference data.

Note :

1.Usually, do not perform this adjustment.

2.Perform this adjustment in an ambient temperature of 22 ˚C to 28 ˚C. Perform it immediately after the power is turned on when the internal temperature of the unit is the same as the ambient temperature of 22 ˚C to 28 ˚C.

3.When D101 has been replaced, perform this adjustment after the temperature of this part has become the ambient temperature.

Adjusting Procedure :

1.Rotate the ˜+ knob and display “TEMP ADJUST”.

2.Press the ENTER/YES button and select the “TEMP ADJUST” mode.

3.“TEMP = [OK]” and the current temperature data will be displayed.

4.To save the data, press the ENTER/YES button.

When not saving the data, press the MENU/NO button.

5.When the ENTER/YES button is pressed, “TEMP = SAVE” will be displayed and turned back to “TEMP ADJUST” display then. When the MENU/NO button is pressed, “TEMP AD- JUST” will be displayed immediatelly.

Specified Value :

The “TEMP =

” should be within “E0 - EF”, “F0 - FF”, “00 -

0F”, “10 - 1F” and “20 - 2F”.

5-10. LASER POWER ADJUSTMENT

Check the IOP value of the optical pick-up before adjustments. (Refer to 5-8. Recording and Displaying IOP Information.)

Connection :

Laser power

 

meter

 

 

 

 

 

 

 

 

Optical pick-up objective lens

Digital volt meter

BD board

CN110 pin 5 (I+3V)

CN110 pin 4 (IOP)

Adjusting Procedure :

1.Set the laser power meter on the objective lens of the optical pick-up. (When it cannot be set properly, press the 0/button or )/± button to move the optical pick-up.)

Connect the digital volt meter to CN110 pin 5 (I+3V) and CN110 pin 4 (IOP).

2.Rotate the ˜+ knob and display “LDPWR ADJUST”. (Laser power : For adjustment)

3.Press the ENTER/YES button once and display “LD 0.9 mW $

”.

4.Rotate the ˜+ knob so that the reading of the laser power meter becomes 0.85 to 0.91 mW. Press the ENTER/YES but- ton after setting the range knob of the laser power meter, and save the adjustment results. (“LD SAVE $ ” will be displayed for a moment.)

5.Then “LD 7.0 mW $ ” will be displayed.

6.Rotate the ˜+ knob so that the reading of the laser power meter becomes 6.9 to 7.1 mW, press the ENTER/YES button and

save it.

Note : Do not perform the emission with 7.0 mW more than 15 seconds continuously.

– 27 –

Image 27
Contents MBU-5A SpecificationsMDS-JE520 MDM-5ASELF-DIAGNOSIS Function Items of Error History Mode Items and Contents Flexible Circuit Board Repairing Specification LabelParts No Exploded Views Table of ContentsDisassembly DiagramsJIG for Checking BD Board Waveform Section Servicing NoteRecord Precedure Criteria for Determination Measure if unsatisfactory Checks Prior to Parts Replacement and AdjustmentsMain Board Component Side Forced ResetFluorescent Indicator Tube and Mechanism Deck Cleaning of Objective Lens of Optical PickupFluorescent Indicator TUBE, LED Complete Lighting Check Attaching the Glass AssemblyServicing Position Binary Retry Cause Display ModeHigher Bits Lower Bits Hexa Cause of Retry Occurring conditionsBit When Binary Higher Bits Lower Bits Hexa DetailsHexadecimal Binary Front Panel Location of Parts and Controls Section GeneralSection Disassembly Glass AssyFront Panel Base Unit and BD Board Slider CAMSW Board and Loading Motor M103 Exiting the Test Mode Section Test ModePrecautions for USE of Test Mode Setting the Test ModeGroup Selecting the Test ModeOperating the Continuous Playback Mode Non-Volatile Memory Mode EEP ModeFunctions of Other Buttons Test Mode Displays Parts Replacement and Adjustment Section Electrical AdjustmentsCreating Continuously Recorded Disc Precautions for Checking Laser Diode EmissinonPrecautions for USE of Optical PICK- UP KMS-260A Precautions for AdjustmentsSpecified Value Temperature Compensation Offset CheckLaser Power Check Checks Prior to RepairsSelf-Recording/playback Check Play Checking MO Error Rate CheckCD Error Rate Check Focus Bias CheckRecording and Displaying the IOP Information Initial Setting of Adjustment ValueTemperature Compensation Offset Adjutment Laser Power AdjustmentTraverse Adjustment Focus Bias Adjustment MO Auto Gain Control Output Level Adjustment Error Rate CheckAuto Gain Control Output Level Adjustment CD Auto Gain Control Output Level AdjustmentAdjusting Points and Connecting Points Circuit Boards Location Section DiagramsREC Digital Block Diagrams BD SectionMDS-SD1 PB Digital outMain Section PBDigital outRECDigital Display Section For schematic diagramsFor printed wiring boards WaveformsSemiconductor Location Printed Wiring Board BD SectionSchematic Diagram BD 1/2 Section Schematic Diagram BD 2/2 Section Schematic Diagram Main 1/2 Section Schematic Diagram Main 2/2 Section Printed Wiring Board Main Section Schematic Diagram Panel Section Printed Wiring Board Panel Section Schematic Diagram Connector Section System Control To HCD-SD1 Printed Wiring Board Connector SectionMDS-SD1 BD Section IC101 IC Block DiagramsIC152 BH6511FS-E2 Main Section IC201 UDA1341TS/N2IC301 LB1641 Connector Section IC774 P82B715TD.118 IC822 M62016FP-E1IC851 M5293L IC PIN Functions IC101 CXA2523AR RF Amplifier BD BoardPin No Pin Name Function IC701 M30610MC-A01FP System Control ∝CON Main Board CHAK-IN Case and Back Panel Section Section Exploded Views67 A-4724-619-A Panel BOARD, Complete FL901 1-517-804-11 Indicator TUBE, FluorescentFront Panel Section Panel SW BoardMechanism Deck Section MDM-5A Insulator F209 4-988-466-21 Spring ELECTROSTATIC, Leaf Base Unit Section MBU-5A HEAD, Over LightMotor ASSY, Sled Section Electrical Parts List Connector Connector Encoder Main Main Ferite InductorLine Filter FILTER, LinePanel Panel SW Screw +B Accessories & Packing Materials FILTER, Clamp Ferrite CoreMANUAL, Instruction English MANUAL, Instruction CHINESESP,HK Hardware ListSony Corporation