7.Then, rotate the
8.Press the ENTER/YES button once and display “LD 0.9 mW $
”. Check that the reading of the laser power meter become 0.85 to 0.91 mW.
9.Press the ENTER/YES button once more and display “LD 7.0 mW $ ”. Check that the reading the laser power meter and digital volt meter satisfy the specified value.
Note down the digital voltmeter reading value.
Specified Value :
Laser power meter reading : 7.0 ± 0.1 mW
Digital voltmeter reading : Optical
(Optical pick-up label)
KMS260A | (For details of the method for checking | |
27X40 | this value, refer to | |
Displaying IOP Information”.) | ||
B0825 | ||
| ||
|
| |
N |
|
Iop = 82.5 mA in this case
Iop (mA) = Digital voltmeter reading (mV)/1 (Ω)
10.Press the MENU/NO button and display “LDPWR CHECK” and stop the laser emission.
(The MENU/NO button is effective at all times to stop the laser emission.)
11.Rotate the
12.Press the ENTER/YES button. When the display becomes Ref=@@@.@ (@ is an arbitrary number), press the ENTER/ YES button to display “Measu=@@@.@” (@ is an arbitrary number).
13.The numbers which can be changed will blink. Input the Iop
value noted down at step 9.
To select the number : Rotate the
To select the digit : Press the CD SYNC/MD WM SYNC but- ton.
14.When the ENTER/YES button is pressed, “Complete!” will be displayed momentarily. The value will be recorded in the
Note 1: After step 4, each time the ENTER/YES button is pressed, the display will be switched between “LD 0.7 mW $ ”,
“LD 6.2 mW $ ”, and “LD Wp $ ”. Nothing needs to be performed here.
5-11. TRAVERSE ADJUSTMENT
Connection :
Oscilloscope
BD board
CN110 pin 3 (TE)
CN110 pin 1 (VC)
V : 0.5 V/div
H : 10 ms/div
Input : DC mode
Adjusting Procedure :
1.Connect an oscilloscope to CN110 pin 3 (TE) and CN110 pin 1 (VC) of the BD board.
2.Load a disc (any available on the market). (Refer to Note 1.)
3.Press the )/± button and move the optical
4.Rotate the
5.Press the ENTER/YES button and display “EFB =
6.Rotate the
scope becomes the specified value.
(When the
(Read power traverse adjustment)
(Traverse Waveform)
A
VC
B
Specification A = B
7.Press the ENTER/YES button and save the result of adjustment to the
for a moment. Then “EFB =
8.Rotate the
scope becomes the specified value.
(When the
(Write power traverse adjustment)
(Traverse Waveform)
A
VC
B
Specification A = B
9.Press the ENTER/YES button, and save the adjustment results in the
10.“EFB =
The optical
– 28 –