Sony MDS-JE640 Initial Setting of Adjustment Value, Temperature Compensation Offset Adjutment

Page 26

5-7. INITIAL SETTING OF ADJUSTMENT VALUE

Note:

Mode which sets the adjustment results recorded in the non-vola- tile memory to the initial setting value. However the results of the temperature compensation offset adjustment will not change to the initial setting value.

If initial setting is performed, perform all adjustments again ex- cluding the temperature compensation offset adjustment.

For details of the initial setting, refer to “5-4. Precautions on Ad- justments” and execute the initial setting before the adjustment as required.

Setting Procedure :

1.Rotate the AMS knob to display “ADJ CLEAR”.

2.Press the YES button. “Complete!” will be displayed momen- tarily and initial setting will be executed, after which “ADJ CLEAR” will be displayed.

5-8. RECORDING AND DISPLAYING THE Iop

INFORMATION

The IOP data can be recorded in the non-volatile memory. The Iop value on the label of the optical pick-up and the Iop value after the adjustment will be recorded. Recording these data eliminates the need to read the label on the optical pick-up.

Recording Procedure :

1.While pressing the AMS knob and x button, connect the power plug to the outlet, and release the AMS knob and x button.

2.Rotate the AMS knob to display “[Service]”, and press the YES button.

3.Rotate the AMS knob to display “Iop.Write”, and press the YES button.

4.The display becomes Ref=@@@.@ (@ is an arbitrary number) and the numbers which can be changed will blink.

5.Input the Iop value written on the optical pick-up. To select the number : Rotate the AMS knob. To select the digit : Press the AMS knob

6.When the YES button is pressed, the display becomes “Measu=@@@.@” (@ is an arbitrary number).

7.As the adjustment results are recorded for the 6 value. Leave it as it is and press the YES button.

8.“Complete!” will be displayed momentarily. The value will be recorded in the non-volatile memory and the display will be- come “Iop Write”.

Display Procedure :

1.Rotate the AMS knob to display “Iop.Read”.

2.“@@.@/##.#” is displayed and the recorded contents are dis- played.

@@.@ indicates the Iop value labeled on the pick-up.

##.# indicates the Iop value after adjustment

3.To end, press the AMS button or MENU/NO button to display “Iop Read”.

5-9. TEMPERATURE COMPENSATION OFFSET ADJUTMENT

Save the temperature data at that time in the non-volatile memory as 25 ˚C reference data.

Note :

1.Usually, do not perform this adjustment.

2.Perform this adjustment in an ambient temperature of 22 ˚C to 28 ˚C. Perform it immediately after the power is turned on when the internal temperature of the unit is the same as the ambient temperature of 22 ˚C to 28 ˚C.

3.When D101 has been replaced, perform this adjustment after the temperature of this part has become the ambient tempera- ture.

Adjusting Procedure :

1.Rotate the AMS knob and display “TEMP ADJUST”.

2.Press the YES button and select the “TEMP ADJUST” mode.

3.“TEMP = [OK]” and the current temperature data will be displayed.

4.To save the data, press the YES button.

When not saving the data, press the MENU/NO button.

5.When the YES button is pressed, “TEMP = SAVE” will be displayed and turned back to “TEMP ADJUST” display then. When the MENU/NO button is pressed, “TEMP ADJUST” will be displayed immediatelly.

Specified Value :

The “TEMP = ” should be within “E0 - EF”, “F0 - FF”, “00 - 0F”, “10 - 1F” and “20 - 2F”.

5-10. LASER POWER ADJUSTMENT

Check the Iop value of the optical pick-up before adjustments. (Refer to 5-8. Recording and Displaying Iop Information.)

Connection :

Laser power

 

 

meter

 

 

 

 

 

 

 

 

Optical pick-up objective lens

Digital volt meter

BD board

CN105 pin 1 (I+3V)

CN105 pin 2 (IOP)

Adjusting Procedure :

1.Set the laser power meter on the objective lens of the optical pick-up. (When it cannot be set properly, press the m button or M button to move the optical pick-up.)

Connect the digital volt meter to CN105 pin 1 (I+3V) and CN105 pin 2 (IOP).

2.Rotate the AMS knob and display “LDPWR ADJUST”. (Laser power : For adjustment)

3.Press the YES button once and display “LD 0.9 mW $ ”.

4.Rotate the AMS knob so that the reading of the laser power meter becomes 0.85 to 0.91 mW. Press the YES button after setting the range knob of the laser power meter, and save the adjustment results. (“LD SAVE $ ” will be displayed for a moment.)

5.Then “LD 7.0 mW $ ” will be displayed.

6.Rotate the AMS knob so that the reading of the laser power

meter becomes 6.9 to 7.1 mW, press the YES button and save it.

Note : Do not perform the emission with 7.0 mW more than 15 seconds continuously.

26

Image 26
Contents Outputs SpecificationsInputs NEWGeneral Supplied accessoriesSELF-DIAGNOSIS Function Three- or five Digit code Cause/Remedy MessageItems of Error History Mode Items and Contents Diagrams Table of ContentsDisassembly Exploded ViewsSection Service Notes Flexible Circuit Board RepairingJIG for Checking BD Board Waveform IOPRecord Precedure Main Board Component Side Checks Prior to Parts Replacement and AdjustmentsForced Reset Retry Cause Display Mode Bit BinaryHexadecimal t Binary Conversion Table Section General Section Disassembly Front Panel SectionMain Board PT BOARD, VOL-SEL BoardMechanism Deck Section MDM-7A BD BoardSetting the Test Mode Section Test ModePrecautions for USE of Test Mode Exiting the Test ModeSelecting the Test Mode Display Details Mark GroupOperating the Continuous Playback Mode MENU/NOError rate display Test Mode DisplaysMode display Functions of Other ButtonsAutomatic SELF-DIAGNOSIS Function When Memory NG is DisplayedMeanings of Other Displays InformationCheck before replacement Section Electrical AdjustmentsParts Replacement and Adjustment Adjustment flow YESPrecautions for Adjustments Precautions for Checking Laser Diode EmissionPrecautions for USE of Optical PICK- UP KMS-260B Using the Continuously Recorded Disc Checks Prior to RepairsAuto Check Other ChecksPlay Check MO Error Rate Check CD Error Rate CheckLaser Power Adjustment Initial Setting of Adjustment ValueTemperature Compensation Offset Adjutment Traverse Adjustment Iop NV SaveFocus Bias Adjustment YESCD Auto Gain Control Output Level Adjustment Error Rate CheckAuto Gain Control Output Level Adjustment MO Auto Gain Control Output Level AdjustmentAdjusting Points and Connecting Points For printed wiring boards Section DiagramsFor schematic diagrams Circuit Boards LocationMDS-JE640 Block Diagrams BD SectionSignal Path Main Section REC AnalogDisplay Board BD BoardMain Board Printed Wiring Board BD Section SemiconductorPIN PIN Function Printed Wiring Board Main Section Side a IC2 Printed Wiring Board Main Section Side BIC1 PIN MDS-JE640 Schematic Diagram Main /3 See page 47 for IC Block Diagrams Printed Wiring Board Power Section Printed Wiring Board Display Section Schematic Diagram Display Section See page 34 for Waveforms IC Block Diagrams IC101 CXA2523AR BD BoardIC400 LA5643 Main Board IC PIN Functions IC101 CXA2523AR RF Amplifier BD BoardMNT0 FOK Mvci Tfdr IC1 M30805SGP System Control Main Board HLDA/ALE Section Exploded Views Chassis SectionPanel ASSY, Front Black AEP,UK,CIS,SP,MY Panel ASSY, Front SilverMechanism MDM-7A 202 220 201 213 215 216 205 218 207Motor ASSY, Sled HEAD, Over LightMotor ASSY, Spindle Motor ASSY, LoadingSection Electrical Parts List IC MC74ACT08DTR2 IC TC7WU04FUTE12RMetal Chip IC BA033FP-E2Display KEY-SW Main PIN, Connector 4P PIN, Connector 3PCONNECTOR, FFC 17P PLUG, Connector 10P DiodeTransistor UN2211-TX IC SN74LVU04ANSRAEP,UK,CIS Transistor UN2111-TXTRANSFORMER, Power SP,MY ConnectorTRANSFORMER, Power CND Composition Circuit BlockVOL-SEL Sony Corporation